SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:lup.lub.lu.se:dc42a5bc-dffd-4350-a7f5-7ebfbadc1153"
 

Sökning: onr:"swepub:oai:lup.lub.lu.se:dc42a5bc-dffd-4350-a7f5-7ebfbadc1153" > Detection of Escher...

Detection of Escherichia coli in water by culture-based amperometric and luminometric methods.

Nistor, Catalin (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Osvik, A (författare)
Davidsson, Richard (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Rose, A (författare)
Wollenberger, U (författare)
Pfeiffer, D (författare)
Emnéus, Jenny (författare)
Lund University,Lunds universitet,Centrum för analys och syntes,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Centre for Analysis and Synthesis,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Fiksdal, L (författare)
visa färre...
 (creator_code:org_t)
2002
2002
Engelska.
Ingår i: Water Science and Technology. - 0273-1223. ; 45:4-5, s. 191-199
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The application of amperometric biosensor- and chemiluminiscence based methods for rapid detection of viable E. coli in water has been investigated. An amplification of the amperometric signal by a factor of 4 was obtained when the cellobiose dehydrogenase (CDH) biosensor was used instead of a plain graphite electrode for detection of b-galactosidase (b-GAL) activity at 22.5 degrees C. A linear correlation was demonstrated for detection time (DT) vs. initial concentrations (logarithmic units) of E. coli IT1 and E. coli in environmental samples, respectively, by use of the CDH biosensor or a chemiluminometric technique. The study has shown that an E. coli concentration > or = 10(4) cfu/100 mL in environmental samples was determined by the CDH biosensor within one working day. However, further reduction of the DT can be obtained, e.g. by increasing the signal amplification factor using other biosensors.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy