SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lindh Christian)
 

Sökning: WFRF:(Lindh Christian) > (1995-1999) > Determination of cy...

Determination of cyclic organic acid anhydrides in air using gas chromatography .2. Sampling and determination of hexahydrophthalic anhydride, methylhexahydrophthalic anhydride, tetrahydrophthalic anhydride and octenylsuccinic anhydride

Jönsson, Bo A (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Lindh, Christian (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Gustavsson, CA (författare)
visa fler...
Welinder, Hans (författare)
Lund University,Lunds universitet,Avdelningen för arbets- och miljömedicin,Institutionen för laboratoriemedicin,Medicinska fakulteten,Division of Occupational and Environmental Medicine, Lund University,Department of Laboratory Medicine,Faculty of Medicine
Pfäffli, P (författare)
visa färre...
 (creator_code:org_t)
1996
1996
Engelska.
Ingår i: Analyst. - 1364-5528. ; 121:9, s. 1285-1290
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Methods for sampling and determination of four organic acid anhydrides are described. The methods were validated in a standard atmosphere and in the work environment. Hexahydrophthalic anhydride (HHPA), methylhexahydrophthalic anhydride (MHHPA), tetrahydrophthalic anhydride (THPA) and octenylsuccinic anhydride (OSA) were sampled using Tenax and Amberlite XAD-2 solid sorbents and determined by GC with flame ionization detection (FID) after elution. The precision was normally better than 10% but for OSA it was up to 19%. The detection limits were 0.1 µg per sample. MHHPA, THPA and OSA were also sampled using bubblers containing aqueous sampling solutions. MHHPA and THPA was derivatized with pentafluorobenzyl bromide (PFBBr) and determined by GC with MS detection. OSA was derivatized by methanol with boron trifluoride catalysis and determined by GC–FID. The precisions for MHHPA and THPA were 4 and 8%, respectively, and the detection limit was < 0.005 µg per sample. The precision for OSA was up to 58% and the detection limit was 0.2 µg per sample. HHPA and MHHPA were also sampled on glass-fibre filters, derivatized with PFBBr, and determined by GC–MS with good results. However, further validations of the filter methods are needed.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Hälsovetenskap -- Arbetsmedicin och miljömedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Health Sciences -- Occupational Health and Environmental Health (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

  • Analyst (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Jönsson, Bo A
Lindh, Christian
Gustavsson, CA
Welinder, Hans
Pfäffli, P
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Arbetsmedicin oc ...
Artiklar i publikationen
Analyst
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy