Evaluation of a new perimetric threshold strategy, SITA, in patients with manifest and suspect glaucoma

  • Artikel/kapitelEngelska1998

Förlag, utgivningsår, omfång ...

  • 1998
  • 5 s.

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:e47c83b3-027d-4281-8da8-5538f1d74315
  • https://lup.lub.lu.se/record/e47c83b3-027d-4281-8da8-5538f1d74315URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • PURPOSE: To evaluate the performance of the new perimetric threshold strategy SITA relative to older methods.METHOD: Thirty-two patients with either glaucoma or ocular hypertension performed two threshold visual field tests with each of three threshold strategies, SITA, Humphrey Full Threshold, and Fastpac. Testing was distributed over three visits, and testing order was balanced between strategies to control for order effects.RESULTS: SITA tests consumed 54% of the time taken by Full Threshold tests on average, and 85% of Fastpac tests; SITA's test times were significantly shorter than those of Full Threshold (p<0.0001) and Fastpac (p=0.0008). Test-retest threshold variability did not differ significantly between strategies. Intertest variability of the pattern deviation analysis was lowest in SITA (p<0.01) relative to both Full Threshold and Fastpac. Both SITA and Fastpac showed higher than expected average sensitivities relative to Full Threshold. SITA and Fastpac showed approximately the same amount of visual field loss. There was a significant relationship between Mean Deviation and the SITA function used to shorten stimulus sequences at points where measurement errors are small (p<0.0001).CONCLUSION: Our results suggest that SITA matches the precision of older thresholding methods, consuming considerably and significantly less test time. This indicates that SITA could replace Full Threshold as the standard clinical test used in glaucoma management, without decreasing the quality of test results.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Heijl, ALund University,Lunds universitet,Oftalmologi (Malmö),Forskargrupper vid Lunds universitet,Ophthalmology (Malmö),Lund University Research Groups(Swepub:lu)ofta-ahe (författare)
  • Oftalmologi (Malmö)Forskargrupper vid Lunds universitet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Acta Ophthalmologica Scandinavica76:3, s. 72-2681395-3907

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bengtsson, B
Heijl, A
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Oftalmologi
Artiklar i publikationen
Acta Ophthalmolo ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy