SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sornmo Leif)
 

Sökning: WFRF:(Sornmo Leif) > Investigating Respi...

Investigating Respiratory Rate Estimation during Paroxysmal Atrial Fibrillation Using an Improved ECG Simulation Model

Kontaxis, Spyridon (författare)
CIBER Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN),University of Zaragoza
Martin-Yebra, Alba (författare)
Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,University of Zaragoza
Petrenas, Andrius (författare)
Kaunas University of Technology
visa fler...
Marozas, Vaidotas (författare)
Kaunas University of Technology
Bailon, Raquel (författare)
University of Zaragoza,CIBER Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN)
Laguna, Pablo (författare)
University of Zaragoza,CIBER Bioengineering, Biomaterials and Nanomedicine (CIBER-BBN)
Sornmo, Leif (författare)
Lund University,Lunds universitet,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2020
2020
Engelska.
Ingår i: 2020 Computing in Cardiology, CinC 2020. - 2325-887X .- 2325-8861. - 9781728173825 ; 2020-September
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The present study addresses the problem of respiratory rate estimation from ECG-derived respiration (EDR) signals during paroxysmal atrial fibrillation (AF). Novel signal-to-noise ratios between various components of the ECG including the influence of respiration, measured by QRS ensemble variance, the amplitude of fibrillatory waves (f-waves), and the QRS amplitude are introduced to characterize EDR performance. Using an improved ECG simulation model accounting for morphological variation induced by respiration, the results show that 1. the error in estimating the respiratory rate increases as a function of the time spent in AF, 2. the leads farthest away from the atria, i.e., V_{4}, V_{5}, V_{6}, exhibit the best performance due to lower f-wave amplitudes, 3. lower errors in leads with similar f-wave amplitude are due to a more pronounced respiratory influence, and 4. the respiratory influence is higher in V_{2}, V_{3}, and V_{4} compared to other precordial leads.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy