Characterization of Changes in P-Wave VCG Loops Following Pulmonary-Vein Isolation
-
- Ortigosa, Nuria (author)
- Polytechnic University of Valencia
-
- Cano, Óscar (author)
- University and Polytechnic Hospital la Fe
-
- Sandberg, Frida (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- 2021-03-09
- 2021
- English.
-
In: Sensors. - : MDPI AG. - 1424-8220. ; 21:5
- Related links:
-
http://dx.doi.org/10... (free)
-
show more...
-
https://www.mdpi.com...
-
https://lup.lub.lu.s...
-
https://doi.org/10.3...
-
show less...
Abstract
Subject headings
Close
- Atrial fibrillation is the most common type of cardiac arrhythmia in clinical practice. Currently, catheter ablation for pulmonary-vein isolation is a well-established treatment for maintaining sinus rhythm when antiarrhythmic drugs do not succeed. Unfortunately, arrhythmia recurrence after catheter ablation remains common, with estimated rates of up to 45%. A better understanding of factors leading to atrial-fibrillation recurrence is needed. Hence, the aim of this study is to characterize changes in the atrial propagation pattern following pulmonary-vein isolation, and investigate the relation between such characteristics and atrial-fibrillation recurrence. Fifty patients with paroxysmal atrial fibrillation who had undergone catheter ablation were included in this study. Time-segment and vectorcardiogram-loop-morphology analyses were applied to characterize P waves extracted from 1 min long 12-lead electrocardiogram segments before and after the procedure, respectively. Results showed that P-wave vectorcardiogram loops were significantly less round and more planar, P waves and PR intervals were significantly shorter, and heart rate was significantly higher after the procedure. Differences were larger for patients who did not have arrhythmia recurrences at 2 years of follow-up; for these patients, the pre- and postprocedure P waves could be identified with 84% accuracy.
Subject headings
- MEDICIN OCH HÄLSOVETENSKAP -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
Keyword
- vectorcardiogram (VCG)
- atrial fibrillation
- P wave
- pulmonary-vein isolation