SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1557 170X OR L773:9781457702204
 

Sökning: L773:1557 170X OR L773:9781457702204 > (2015-2019) > Automatic segmentat...

Automatic segmentation of lungs in SPECT images using active shape model trained by meshes delineated in CT images

Grigorios-Aris, Cheimariotis (författare)
Aristotle University of Thessaloniki
Al-Mashat, Mariam (författare)
Lund University,Lunds universitet,Hjärt-MR-gruppen i Lund,Forskargrupper vid Lunds universitet,Lund Cardiac MR Group,Lund University Research Groups,Skåne University Hospital
Kostas, Haris (författare)
Aristotle University of Thessaloniki
visa fler...
Anthony, Aletras H. (författare)
Aristotle University of Thessaloniki
Jögi, Jonas (författare)
Lund University,Lunds universitet,Hjärt-MR-gruppen i Lund,Forskargrupper vid Lunds universitet,Lund Cardiac MR Group,Lund University Research Groups,Skåne University Hospital
Bajc, Marika (författare)
Lund University,Lunds universitet,Nuklearmedicinsk lungdiagnostik,Klinisk fysiologi, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Lung nuclear medicine diagnostics,Clinical Physiology (Lund),Section V,Department of Clinical Sciences, Lund,Faculty of Medicine,Skåne University Hospital
Nicolaos, Maglaveras (författare)
Aristotle University of Thessaloniki
Heiberg, Einar (författare)
Lund University,Lunds universitet,Hjärt-MR-gruppen i Lund,Forskargrupper vid Lunds universitet,Lund Cardiac MR Group,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
2016
2016
Engelska 4 s.
Ingår i: 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2016. - 9781457702204 ; 2016-October, s. 1280-1283
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper presents a fully automated method for segmentation of 3D SPECT ventilation and perfusion images. It relies on statistical information on lung shape derived by CT manual segmentation and its main processing steps are: shape model extraction, binary segmentation, positioning of mean shape in SPECT images and iterative shape adaptation based on intensity profiles and on what is considered 'plausible' lung shape. The Active Shape Model is used to generate accurate anatomic results in SPECT images with functional information and thus unclear borders, especially in the case of pathologies. The method was compared against ground truth manual segmentation on CT images, using volumetric, difference dice coefficient, sensitivity and precision.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy