SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hedström Martin)
 

Sökning: WFRF:(Hedström Martin) > A sensitive and rea...

A sensitive and real-time assay of trypsin by using molecular imprinting-based capacitive biosensor

Ertürk, Gizem (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH,CapSenze Biosystems AB
Hedström, Martin (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH,CapSenze HB
Mattiasson, Bo (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH,CapSenze HB
 (creator_code:org_t)
Elsevier BV, 2016
2016
Engelska 9 s.
Ingår i: Biosensors and Bioelectronics. - : Elsevier BV. - 0956-5663. ; 86, s. 557-565
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Use of a highly sensitive, selective capacitive biosensor is reported for label-free, real-time, easy and rapid detection of trypsin by using the microcontact imprinting method. Real-time trypsin detection was performed with trypsin-imprinted (trypsin-MIP) capacitive electrodes using standard trypsin solutions in the concentration range of 1.0×10−13–1.0×10−7 M with a detection limit of 3.0×10−13 M. Selectivity and cross-reactivity of the system were tested by using competing proteins including chymotrypsin (chy), bovine serum albumin (BSA), lysozyme (lyz) and cytochrome c (cyt c) in singular and competitive manner and the selectivity of the system was determined with the selectivity coefficients of approximately 705.1, 6.5, 6.4 and 5.1 for chy, BSA, lyz and cyt c, respectively. The trypsin-MIP capacitive electrode was used for ~80 assays during 2 months and retained its binding property during all that time with a decrease of approximately 2.3% in the signal amplitude. In the last step, trypsin activity was measured by using Nα-Benzoyl-D, L-arginine 4-nitroanilide hydrochloride (BAPNA) as the substrate with spectrophotometer at 410 nm. The trypsin activity was measured as 9 mU/mL by spectrophotometer while the amount of captured enzyme calculated from the capacitive system was 7.9 mU/mL which shows the correlation between two methods. From the comparison it is obvious that the new method is an attractive alternative for assaying trypsin and the developed capacitive system might be used successfully to monitor label-free, real-time enzymatic activity of different proteases in a sensitive, rapid, cost-effective manner for different applications.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)

Nyckelord

Capacitive biosensor
Cross-reactivity
Microcontact imprinting
Selectivity

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ertürk, Gizem
Hedström, Martin
Mattiasson, Bo
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
Artiklar i publikationen
Biosensors and B ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy