SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Van Huffel Sabine)
 

Sökning: WFRF:(Van Huffel Sabine) > External Validation...

External Validation of Diagnostic Models to Estimate the Risk of Malignancy in Adnexal Masses

Van Holsbeke, Caroline (författare)
Van Calster, Ben (författare)
Bourne, Tom (författare)
visa fler...
Ajossa, Silvia (författare)
Testa, Antonia C. (författare)
Guerriero, Stefano (författare)
Fruscio, Robert (författare)
Lissoni, Andrea Alberto (författare)
Czekierdowski, Artur (författare)
Savelli, Luca (författare)
Van Huffel, Sabine (författare)
Valentin, Lil (författare)
Lund University,Lunds universitet,Obstetrisk, gynekologisk och prenatal ultraljudsdiagnostik,Forskargrupper vid Lunds universitet,Obstetric, Gynaecological and Prenatal Ultrasound Research,Lund University Research Groups
Timmerman, Dirk (författare)
visa färre...
 (creator_code:org_t)
2012
2012
Engelska.
Ingår i: Clinical Cancer Research. - 1078-0432. ; 18:3, s. 815-825
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To externally validate and compare the performance of previously published diagnostic models developed to predict malignancy in adnexal masses. Experimental Design: We externally validated the diagnostic performance of 11 models developed by the International Ovarian Tumor Analysis (IOTA) group and 12 other (non-IOTA) models on 997 prospectively collected patients. The non-IOTA models included the original risk of malignancy index (RMI), three modified versions of the RMI, six logistic regression models, and two artificial neural networks. The ability of the models to discriminate between benign and malignant adnexal masses was expressed as the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, and likelihood ratios (LR+, LR-). Results: Seven hundred and forty-two (74%) benign and 255 (26%) malignant masses were included. The IOTA models did better than the non-IOTA models (AUCs between 0.941 and 0.956 vs. 0.839 and 0.928). The difference in AUC between the best IOTA and the best non-IOTA model was 0.028 [95% confidence interval (CI), 0.011-0.044]. The AUC of the RMI was 0.911 (difference with the best IOTA model, 0.044; 95% CI, 0.024-0.064). The superior performance of the IOTA models was most pronounced in premenopausal patients but was also observed in postmenopausal patients. IOTA models were better able to detect stage I ovarian cancer. Conclusion: External validation shows that the IOTA models outperform other models, including the current reference test RMI, for discriminating between benign and malignant adnexal masses. Clin Cancer Res; 18(3); 815-25. (C)2011 AACR.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy