SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wisén Anita)
 

Sökning: WFRF:(Wisén Anita) > Is Ross treadmill m...

  • Garland, StephenLund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups,Department of Health Sciences, Physiotherapy Research Group, Lund University, Lund, Sweden; (författare)

Is Ross treadmill method an alternative to Åstrand cycle ergometer method?

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • 2017-06-14
  • Informa UK Limited,2017
  • 6 s.

Nummerbeteckningar

  • LIBRIS-ID:oai:lup.lub.lu.se:ed7c60cc-ab88-43d9-8074-40ca78ea7c64
  • https://lup.lub.lu.se/record/ed7c60cc-ab88-43d9-8074-40ca78ea7c64URI
  • https://doi.org/10.1080/21679169.2017.1340515DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-67144URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Aims: To assess the agreement between the Ross treadmill method and the Åstrand ergometer cycle method, and the repeatability of each method. Methodology: Twenty healthy people aged 22.5 ± 2.2 years were tested on two different days, each day with both methods with a pause of 30 min between the tests. The tests were executed in the reverse order the following test day. Major findings: There was no statistical difference between the methods. The correlation (R) between the methods was 0.85. The mean difference (95% CI) of the methods was 0.050 (0.046–0.054) L/min and the limit of the agreement (mean difference ±2SD) was 0.81 L/min. No significant differences in test-retest were shown for either test. The mean difference for Åstrand tests was 0.12 L/min and 0.08 L/min for the Ross tests. The coefficient of repeatability was 0.88 L/min (23%) for the Åstrand test, and 0.78 L/min (20%) for the Ross test. Conclusion: The Ross treadmill test could be used as an alternative to the Åstrand cycle ergometer test, showing good agreement and repeatability. The large variation should be considered when estimating aerobic capacity on an individual level, although either method could be used for group studies where maximal measurements are not possible.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ingesson, PontusHelsingborgs Hospital, Helsingborg, Sweden; (författare)
  • Petersson, HenrikCity of Malmö,Malmö Municipality, Malmö, Sweden (författare)
  • Wisén, AnitaLund University,Lunds universitet,Människan i rörelse: hälsa och rehabilitering,Forskargrupper vid Lunds universitet,Human Movement: health and rehabilitation,Lund University Research Groups,Department of Health Sciences, Physiotherapy Research Group, Lund University, Lund, Sweden;(Swepub:lu)sjuk-wan (författare)
  • Människan i rörelse: hälsa och rehabiliteringForskargrupper vid Lunds universitet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Journal of Physiotherapy: Informa UK Limited19:3, s. 167-1722167-91692167-9177

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Garland, Stephen
Ingesson, Pontus
Petersson, Henri ...
Wisén, Anita
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Hälsovetenskap
och Sjukgymnastik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Klinisk laborato ...
Artiklar i publikationen
European Journal ...
Av lärosätet
Lunds universitet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy