Quantitative serial imaging of an I-124 anti-CEA monoclonal antibody in tumor-bearing mice
-
Bading, James R. (författare)
-
Horling, Magnus (författare)
-
Williams, Lawrence E. (författare)
-
visa fler...
-
Colcher, David (författare)
-
Raubitschek, Andrew (författare)
-
- Strand, Sven-Erik (författare)
- Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
-
visa färre...
-
(creator_code:org_t)
- Mary Ann Liebert Inc, 2008
- 2008
- Engelska.
-
Ingår i: Cancer Biotherapy & Radiopharmaceuticals. - : Mary Ann Liebert Inc. - 1557-8852 .- 1084-9785. ; 23:4, s. 399-409
- Relaterad länk:
-
http://dx.doi.org/10...
-
visa fler...
-
https://europepmc.or...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Objective: The 4.2-day half-life I-124 favors its use for positron emission tomography (PET) of monoclonal antibodies (mAbs). However, high positron energy and beta(+)-associated cascade gamma rays pose image resolution and background noise problems for I-124. This study evaluated quantitative PET of an I-124 mAb in tumor-bearing mice. Methods: An R4 microPET (TM) (Siemens/CTIMI, Knoxville, TN) was used with standard energy and coincidence timing windows (350-750 keV and 6 ns, respectively), delayed random coincidence subtraction, iterative image reconstruction, and no attenuation or scatter correction. Image resolution, contrast, and response linearity were compared for I-124 and F-18, using phantoms. Nude mice bearing human colon tumors (LS-174T) were injected intravenously with a chimeric I-124 anti-CEA mAb (cT84.66) and imaged serially 1 hour to 7 clays postinjection. Venous blood was sampled to validate image-derived blood curves. Mice were sacrificed after the final scan, and the biodistribution of I-124 was measured by direct tissue assay. Images were converted to units of kBq/g for each tissue of interest by comparing the final scans with the direct assays. Results: Measured resolution (FWHM) 0-16 mm from? the scanner axis was. 2.3-2.7 mm for I-124 versus 1.9-2.0 mm for F-18. Due to true coincidence e vents between annihilation photons and cascade gamma rays, background was greater for I-124 than F-18, but the signal-to-background ratio was still more than 20, and I-124 image intensities varied linearly with activity concentration. Tissue-based calibration worked well (i.e., PET blood curves agreed with direct measurements within 12% at all time points), while calibration, based on a cylindrical phantom approximating the mouse body, yielded tumor quantitation that was 46%-66% low, compared with direct assay. Conclusions: Images of quantitative accuracy sufficient for biodistribution. measurements can be obtained from tumor-bearing mice by using I-124 anti-CEA mAbs with standard. microPET acquisition and processing techniques, provided the calibration is based on the direct assay of excised tissue samples.
Ämnesord
- MEDICIN OCH HÄLSOVETENSKAP -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
- MEDICAL AND HEALTH SCIENCES -- Clinical Medicine -- Cancer and Oncology (hsv//eng)
Nyckelord
- molecular imaging
- antibody
- cancer
- PET
- radioimmunotherapy
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas