SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Strand Sven Erik))
 

Sökning: (WFRF:(Strand Sven Erik)) > (2005-2009) > Quantitative serial...

Quantitative serial imaging of an I-124 anti-CEA monoclonal antibody in tumor-bearing mice

Bading, James R. (författare)
Horling, Magnus (författare)
Williams, Lawrence E. (författare)
visa fler...
Colcher, David (författare)
Raubitschek, Andrew (författare)
Strand, Sven-Erik (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
visa färre...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2008
2008
Engelska.
Ingår i: Cancer Biotherapy & Radiopharmaceuticals. - : Mary Ann Liebert Inc. - 1557-8852 .- 1084-9785. ; 23:4, s. 399-409
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: The 4.2-day half-life I-124 favors its use for positron emission tomography (PET) of monoclonal antibodies (mAbs). However, high positron energy and beta(+)-associated cascade gamma rays pose image resolution and background noise problems for I-124. This study evaluated quantitative PET of an I-124 mAb in tumor-bearing mice. Methods: An R4 microPET (TM) (Siemens/CTIMI, Knoxville, TN) was used with standard energy and coincidence timing windows (350-750 keV and 6 ns, respectively), delayed random coincidence subtraction, iterative image reconstruction, and no attenuation or scatter correction. Image resolution, contrast, and response linearity were compared for I-124 and F-18, using phantoms. Nude mice bearing human colon tumors (LS-174T) were injected intravenously with a chimeric I-124 anti-CEA mAb (cT84.66) and imaged serially 1 hour to 7 clays postinjection. Venous blood was sampled to validate image-derived blood curves. Mice were sacrificed after the final scan, and the biodistribution of I-124 was measured by direct tissue assay. Images were converted to units of kBq/g for each tissue of interest by comparing the final scans with the direct assays. Results: Measured resolution (FWHM) 0-16 mm from? the scanner axis was. 2.3-2.7 mm for I-124 versus 1.9-2.0 mm for F-18. Due to true coincidence e vents between annihilation photons and cascade gamma rays, background was greater for I-124 than F-18, but the signal-to-background ratio was still more than 20, and I-124 image intensities varied linearly with activity concentration. Tissue-based calibration worked well (i.e., PET blood curves agreed with direct measurements within 12% at all time points), while calibration, based on a cylindrical phantom approximating the mouse body, yielded tumor quantitation that was 46%-66% low, compared with direct assay. Conclusions: Images of quantitative accuracy sufficient for biodistribution. measurements can be obtained from tumor-bearing mice by using I-124 anti-CEA mAbs with standard. microPET acquisition and processing techniques, provided the calibration is based on the direct assay of excised tissue samples.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Nyckelord

molecular imaging
antibody
cancer
PET
radioimmunotherapy

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy