SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Goh Chee Leok))
 

Sökning: (WFRF:(Goh Chee Leok)) > Correlation between...

Correlation between Stated and Measured Concentrations of Acrylate and Methacrylate Allergens in Patch-Test Preparations

Goon, Anthony (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Bruze, Magnus (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Zimerson, Erik (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
visa fler...
Sörensen, Östen (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
Goh, Chee-Leok (författare)
Koh, David Soo-Quee (författare)
Isaksson, Marléne (författare)
Lund University,Lunds universitet,Yrkes- och miljödermatologi,Forskargrupper vid Lunds universitet,Occupational and Environmental Dermatology,Lund University Research Groups
visa färre...
 (creator_code:org_t)
Mary Ann Liebert Inc, 2011
2011
Engelska.
Ingår i: Dermatitis. - : Mary Ann Liebert Inc. - 1710-3568. ; 22:1, s. 27-32
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Contact allergy to acrylates and methacrylates is not uncommon. The allergy is confirmed by patch-testing patients with commercial patch-test preparations. Objective: To investigate acrylate and methacrylate allergens used for patch testing in nine different dermatology departments from Europe, America, Asia, and Australia. Methods: The acrylate and methacrylate (methyl methacrylate, 2-hydroxypropyl acrylate, 2-hydroxyethyl methacrylate, ethylene glycol dimethacrylate, and triethylene glycol diacrylate) allergen samples were analyzed with high-performance liquid chromatography to measure the allergen content. Results: Variation in measured versus stated concentrations was seen in these samples. The ratio of measured to stated concentrations ranged from 0.11 to 1.1. Only 22 (63%) of 35 samples were within the arbitrary acceptable limits of 80 to 120% of the stated concentrations. Conclusion: The results may have implications for individual diagnosis and prevention and when test results from various centers are compared.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Lungmedicin och allergi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Respiratory Medicine and Allergy (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy