SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0161 5505 OR L773:1535 5667 OR L773:2159 662X
 

Sökning: L773:0161 5505 OR L773:1535 5667 OR L773:2159 662X > (1975-1979) > Quantitative lympho...

Quantitative lymphoscintigraphy. I. Basic concepts for optimal uptake of radiocolloids in the parasternal lymph nodes of rabbits

Strand, S. E. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
Persson, B. R.R. (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Lund,Sektion V,Institutionen för kliniska vetenskaper, Lund,Medicinska fakulteten,Medical Radiation Physics, Lund,Section V,Department of Clinical Sciences, Lund,Faculty of Medicine
 (creator_code:org_t)
1979
1979
Engelska.
Ingår i: Journal of Nuclear Medicine. - 0161-5505. ; 20:10, s. 1038-1046
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The activity-size distribution of radiocolloids has been studied using gel-chromatography scanning (GCS) of columns filled with Sepharose 4B gel. Rabbits were injected subcutaneously with the colloid of interest, laid supine beneath a gamma camera, and imaged every 15 sec for 2 to 4 hr. From the stored data, the uptakes in the parasternal lymph nodes were analyzed in terms of a two-compartment model, and the rate constants measured. The substances tested were Au-198 colloid, Tc-99m antimony sulfide colloid, Tc-99m tin colloid, Tc-99m phytate, and Tc99m sulfur colloid. It was shown that the optimal particle size for the colloid is in the range 1-10 nm. The largest and most rapid uptake was found for Au-198 colloid, with a particle size of 5 nm, which appeared as a single peak in the GCS spectrum. The percentage uptake after 2 hr for Au-198 colloid was 8%, while it was 5% for antimony sulfide colloid, which was the best of the Tc-99m-labeled colloids. The GCS spectrum for the antimony product showed a single-peaked size distribution with a somewhat broader range: 5-15 nm. The particles of the other colloids were either too large to pass into the lymphatic system, or too small to be trapped.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Strand, S. E.
Persson, B. R.R.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Journal of Nucle ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy