SwePub
Sök i LIBRIS databas

  Extended search

L773:1551 7616 OR L773:0094 243X
 

Search: L773:1551 7616 OR L773:0094 243X > (2000-2004) > Elliptically polari...

Elliptically polarised soft X-rays produced using a local bump in MAX II characterisation of the degree of polarisation

Hunter Dunn, Jonathan (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Hahlin, A (author)
Karis, O (author)
show more...
Arvanitis, Dimitri (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
LeBlanc, Gregory (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Andersson, Åke (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
Lindgren, Lars-Johan (author)
Lund University,Lunds universitet,MAX IV-laboratoriet,MAX IV Laboratory
show less...
 (creator_code:org_t)
AIP, 2004
2004
English.
In: AIP Conference Proceedings. - : AIP. - 1551-7616 .- 0094-243X. ; 705, s. 65-68
  • Conference paper (peer-reviewed)
Abstract Subject headings
Close  
  • MAX-lab has introduced a local perturbation to the electron orbit of the MAX II storage ring, providing users at the SX700 monochromator beam line, D1011, with elliptically polarised soft X-rays. This is achieved by using corrector magnets to send the electron orbit on an ascending or descending trajectory through the dipole magnet source. This simple "bump" approach has many advantages over and above insertion device based solutions. To illustrate the potential of the approach, the degree of circular polarisation, Pc, has both been calculated and measured. The calculation was made by applying the Stokes formalism to the intensities given by the standard dipole emission formula. Experimentally Pc was characterised using X-ray magnetic circular dichroism measurements. In such experiments magnetic contrast scales directly proportional to Pc. Using a 25 atomic layer bcc Fe film deposited on the Cu(100) surface as a calibration standard the spin moment, ms, was determined. By comparing the values of ms obtained here with those reported earlier, the degree of circular polarisation could be estimated. At ~715 eV the calculated and measured values of Pc are 0.93 and 0.85, respectively

Subject headings

NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)

Keyword

X-ray magnetic circular dichroism measurements
magnetic contrast
atomic layer bcc Fe film
Cu(100) surface
calibration standard
spin moment
dipole emission formula
Stokes formalism
circular polarisation degree
insertion device based solutions
dipole magnet source
corrector magnets
D1011
SX700 monochromator beam line
electron orbit
local perturbation
MAX II storage ring
local bump
elliptically polarised soft X-rays
soft X-rays production

Publication and Content Type

kon (subject category)
ref (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view