SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wallentén Petter)
 

Sökning: WFRF:(Wallentén Petter) > (2015-2019) > Hygrothermal assess...

Hygrothermal assessment of internally added thermal insulation on external brick walls in Swedish multifamily buildings

Abdul Hamid, Akram (författare)
Lund University,Lunds universitet,Avdelningen för Byggnadsfysik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Physics,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
Wallentén, Petter (författare)
Lund University,Lunds universitet,Avdelningen för Byggnadsfysik,Institutionen för bygg- och miljöteknologi,Institutioner vid LTH,Lunds Tekniska Högskola,Division of Building Physics,Department of Building and Environmental Technology,Departments at LTH,Faculty of Engineering, LTH
 (creator_code:org_t)
Elsevier BV, 2017
2017
Engelska 12 s.
Ingår i: Building and Environment. - : Elsevier BV. - 0360-1323. ; 123, s. 351-362
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Proper and efficient renovation requires understanding the behavior of existing buildings and of different building materials. Analyzing hygrothermal measurements in two case studies, one with and the other without an internally added thermal insulation system, enabled us to identify factors of critical importance for further assessment through simulations, and to validate a hygrothermal simulation model of a solid brick masonry wall, a model used then to assess internally added thermal insulation systems of different types. A mold resistance design (MRD) model shows that, in connection with all internally added thermal insulation systems, the risk of mold growth is appreciable when brought on by solar driven vapor from the exterior. This, if biological material is present in either of two critical areas, those of the boundary between the thermal insulation and either 1) the existing masonry wall, or 2) the exterior surface of an internally added vapor barrier. Furthermore, assessments of corrosion risks are conducted for two critical placements of the bed-joint reinforcement. At a depth of 30 mm from the exterior surface, the corrosion risk was found to be less with use of capillary-active vapor-open systems than when no thermal insulation was employed, other systems increase the corrosion risk. At a depth of 90 mm, all thermal insulation systems increase the corrosion risk. Excluding precipitation uptake eliminates all risks, showing that this is the most crucial factor. Solutions that limit this uptake or increase the drying-out rate should thus be considered beneficial.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)

Nyckelord

Brick
Hygrothermal
Insulation
Masonry
Moisture
Renovation

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abdul Hamid, Akr ...
Wallentén, Pette ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
Artiklar i publikationen
Building and Env ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy