Assessment of Ultra-Short Heart Variability Indices Derived by Smartphone Accelerometers for Stress Detection
-
- Landreani, Federica (author)
- Polytechnic University of Milan
-
- Faini, Andrea (author)
- Istituto Auxologico Italiano
-
- Martin-Yebra, Alba (author)
- Lund University,Lunds universitet,Avdelningen för Biomedicinsk teknik,Institutionen för biomedicinsk teknik,Institutioner vid LTH,Lunds Tekniska Högskola,Department of Biomedical Engineering,Departments at LTH,Faculty of Engineering, LTH,Polytechnic University of Milan
-
show more...
-
- Morri, Mattia (author)
- Polytechnic University of Milan
-
- Parati, Gianfranco (author)
- Istituto Auxologico Italiano,University of Milano-Bicocca
-
- Caiani, Enrico Gianluca (author)
- Polytechnic University of Milan,CNR Institute of Electronics, Computer and Telecommunication Engineering (IEIIT)
-
show less...
-
(creator_code:org_t)
- 2019-08-28
- 2019
- English.
-
In: Sensors (Basel, Switzerland). - : MDPI AG. - 1424-8220. ; 19:17
- Related links:
-
http://dx.doi.org/10... (free)
-
show more...
-
https://www.mdpi.com...
-
https://lup.lub.lu.s...
-
https://doi.org/10.3...
-
show less...
Abstract
Subject headings
Close
- Body acceleration due to heartbeat-induced reaction forces can be measured as mobile phone accelerometer (m-ACC) signals. Our aim was to test the feasibility of using m-ACC to detect changes induced by stress by ultra-short heart rate variability (USV) indices (standard deviation of normal-to-normal interval-SDNN and root mean square of successive differences-RMSSD). Sixteen healthy volunteers were recruited; m-ACC was recorded while in supine position, during spontaneous breathing at rest conditions (REST) and during one minute of mental stress (MS) induced by arithmetic serial subtraction task, simultaneous with conventional electrocardiogram (ECG). Beat occurrences were extracted from both ECG and m-ACC and used to compute USV indices using 60, 30 and 10s durations, both for REST and MS. A feasibility of 93.8% in the beat-to-beat m-ACC heart rate series extraction was reached. In both ECG and m-ACC series, compared to REST, in MS the mean beat duration was reduced by 15% and RMSSD decreased by 38%. These results show that short term recordings (up to 10 s) of cardiac activity using smartphone's accelerometers are able to capture the decrease in parasympathetic tone, in agreement with the induced stimulus.
Subject headings
- TEKNIK OCH TEKNOLOGIER -- Medicinteknik -- Medicinsk apparatteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Medical Engineering -- Medical Equipment Engineering (hsv//eng)
Keyword
- accelerometers
- ballistocardiography
- seismocardiography
- smartphone
- stress evaluation
- ultra-short heart rate variability