SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Hedström Martin)
 

Sökning: WFRF:(Hedström Martin) > Automated flow-inje...

Automated flow-injection immunosensor based on current pulse capacitive measurements

Erlandsson, Dag (författare)
Teeparuksapun, Kosin (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Mattiasson, Bo (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa fler...
Hedström, Martin (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
Elsevier BV, 2014
2014
Engelska.
Ingår i: Sensors and Actuators B: Chemical. - : Elsevier BV. - 0925-4005. ; 190, s. 295-304
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This document describes a new concept for assessing capacitance based on a constant current pulse to the biosensor transducer. The biosensor has a working electrode that is coated with an insulating molecular layer including a ligand which forms an affinity surface. A sensor electrode is brought into contact with electrolyte solution, and the new measuring principle then involves steps where three different constant currents (I-1, I-2 and I-3) are serially pulsed on the sensor surface during pre-determined time periods. The potential that is built up (rising) across the sensor surface is sampled every 6.8 mu s. The inclination of the registered potential profile corresponding to the current pulsed was utilized to calculate both capacitance and resistance. The new current-based measurement method shows a 10-fold increase in stability for the capacitive measurement as compared to the potential pulse technique. Quantitation of HIV-1 p24 using monoclonal anti-HIV-1 p24 antibodies was used as a model system for the evaluation of the technique. The binding of HIV-1 p24 antigens to the immobilized antibodies causes the capacitance to decrease. The change in capacitance was proportional to the concentration of HIV-1 p24. The capacitance measurement using the current pulse method offers a stable sensing technique with a broad range of potential applications. (C) 2013 Elsevier B. V. All rights reserved.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Nyckelord

Current pulse
Capacitive
Automated flow-injection
HIV-1 p24

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Erlandsson, Dag
Teeparuksapun, K ...
Mattiasson, Bo
Hedström, Martin
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
Artiklar i publikationen
Sensors and Actu ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy