SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Ekberg Lena)
 

Search: WFRF:(Ekberg Lena) > What margins should...

What margins should be added to the clinical target volume in radiotherapy treatment planning for lung cancer?

Ekberg, Lars (author)
Holmberg, Ola (author)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Wittgren, Lena (author)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
show more...
Bjelkengren, Göran (author)
Lund University,Lunds universitet,Institutionen för kliniska vetenskaper, Malmö,Medicinska fakulteten,Department of Clinical Sciences, Malmö,Faculty of Medicine
Landberg, Torsten (author)
Lund University,Lunds universitet,Medicinska fakulteten,Faculty of Medicine
show less...
 (creator_code:org_t)
1988
1988
English.
In: Radiotherapy and Oncology. - 1879-0887. ; 48:1, s. 71-77
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • BACKGROUND: The planning target volume in radiotherapy treatment planning takes into account both movements of the clinical target volume (CTV) and set-up deviations. MATERIALS AND METHODS: A group of patients who received radiotherapy for lung cancer were studied. In order to measure the CTV movements due to respiration and other internal organ motions, fluoroscopy was performed for 20 patients. To study the accuracy and reproducibility of patient and beam set-up, 553 electronic portal images from 20 patients were evaluated. Discrepancies between planned and actual field positions were measured and the systematic and random errors were identified. The combined effect of these geometrical variations was evaluated. RESULTS: The average CTV movement with quiet respiration was about 2.4 mm in the medio-lateral and dorso-ventral directions. Movement in the cranio-caudal direction was on average 3.9 mm with a range of 0-12 mm. The systematic set-up errors were on average 2.0 mm in the transversal plane and 3.0 mm in the cranio-caudal direction. The random errors can be described by their standard deviations of 3.2 and 2.6 mm. In this study, the combined effect of the two parameters (CTV movement and set-up deviations) varied between 7.5 and 10.3 mm in different anatomical directions. CONCLUSIONS: In our daily clinical routine, we use a margin of 11 mm in the transversal plane and 15 mm cranially and caudally, also taking into account other unquantified variations and uncertainties.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Cancer och onkologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cancer and Oncology (hsv//eng)

Publication and Content Type

art (subject category)
ref (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Ekberg, Lars
Holmberg, Ola
Wittgren, Lena
Bjelkengren, Gör ...
Landberg, Torste ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Cancer and Oncol ...
Articles in the publication
Radiotherapy and ...
By the university
Lund University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view