SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1526 6028
 

Sökning: L773:1526 6028 > Integration of a Cu...

Integration of a Custom-Made Fenestration to Simplify Acute Reno-Visceral In Situ Aortic Repair

Berczeli, Marton (författare)
Semmelweis University,Skåne University Hospital
Sonesson, Björn (författare)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups,Skåne University Hospital
Karelis, Angelos (författare)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups,Skåne University Hospital
visa fler...
Oderich, Gustavo S. (författare)
University of Texas Health Science Center at Houston
Dias, Nuno V. (författare)
Lund University,Lunds universitet,Vaskulära sjukdomar - kliniska studier,Forskargrupper vid Lunds universitet,Vascular Diseases - Clinical Research,Lund University Research Groups,Skåne University Hospital
visa färre...
 (creator_code:org_t)
Engelska.
Ingår i: Journal of Endovascular Therapy. - 1526-6028.
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: To illustrate the technique of antegrade in situ laser fenestration (ISLF) on a predesign custom-manufactured stent-graft with single reinforced fenestration for use in emergency endovascular repair of complex abdominal aortic aneurysms (AAAs). Technique: A short custom-made device (CMD) fenestrated graft was predesigned with a single preloaded 8 mm strut-free fenestration at 12 o’clock position. A modified preloaded system was used to allow unilateral access from the distal port if necessary. After bilateral percutaneous femoral access, the graft was deployed under fusion guidance with the CMD fenestration matching the superior mesenteric artery (SMA) origin and immediately bridged as per standard technique. The aneurysm was then excluded with a bifurcated device. A large steerable sheath was used to allow for sequential antegrade laser in situ fenestration and stenting of the renal arteries. Conclusions: Single-vessel customized short fenestrated grafts for the SMA and antegrade in situ laser renal fenestrations are technically feasible for repair of acute complex AAAs even after previous infrarenal reconstruction. It could become an off-the-shelf solution to limit aortic coverage and reno-visceral ischemia, even in patients with a narrow aortic diameter at the renal level. Clinical Impact: Single-vessel precustomized short fenestrated grafts for the SMA combined with renal artery antegrade ISLF can be a feasible option for the acute repair of patients with complex aneurysms and a narrow aortic diameter at the reno-visceral segment. It may limit aortic coverage and reno-visceral ischemic time and also be applicable after previous infrarenal endovascular aneurysm repair (EVAR).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Nyckelord

acute aortic treatment
antegrade laser fenestration
endovascular aortic repair
in situ laser fenestration
juxtarenal aortic aneurysm
pararenal aortic aneurysm
ruptured aortic aneurysm

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Berczeli, Marton
Sonesson, Björn
Karelis, Angelos
Oderich, Gustavo ...
Dias, Nuno V.
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Journal of Endov ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy