SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Tingberg Anders)
 

Sökning: WFRF:(Tingberg Anders) > The Effect of Breas...

The Effect of Breast Positioning on Breast Compression in Mammography: a Pressure Distribution Perspective

Dustler, Magnus (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
Andersson, Ingvar (författare)
Lund University,Lunds universitet,Institutionen för translationell medicin,Medicinska fakulteten,Department of Translational Medicine,Faculty of Medicine
Förnvik, Daniel (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa fler...
Tingberg, Anders (författare)
Lund University,Lunds universitet,Medicinsk strålningsfysik, Malmö,Forskargrupper vid Lunds universitet,Medical Radiation Physics, Malmö,Lund University Research Groups
visa färre...
 (creator_code:org_t)
SPIE, 2012
2012
Engelska.
Ingår i: Medical Imaging 2012: Physics of Medical Imaging. - : SPIE. - 0277-786X .- 1996-756X. ; 8313
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The standard procedure at mammography is to compress the breast in order to improve image quality, better separate tissue components and reduce absorbed dose to the breast. Traditionally, compression guidelines have been based on applied force, rather than actual thickness reduction. Structures such as the pectoral muscle are stiffer than breast tissue and if compressed along with it, as in the MLO-projection, might absorb much of the applied force. This study investigated the difference in compression of breasts before and after they were repositioned to exclude 1 cm of the juxtathoracic part. Twenty-one women were included in the study. The distribution of compression pressure was measured using thin FSR (Force Sensing Resistor) pressure sensors attached to the compression paddle. Breast thickness and compression force were measured by the mammographic device. Compared to standard positioning the repositioned breasts were thinner by 4.4 +/- 2.3 mm (P < 0.001) (from 50.3 mm to 45.9 mm) and had a 12.3 +/- 24.5 cm(2) (P = 0.032) larger area over which pressure was distributed (from 97.6 cm(2) to 109.9 cm(2)), despite less of the breast being included in the projection. This indicates that the inclusion of the pectoral muscle and other juxtathoracic structures in the MLO-projection substantially affects pressure distribution and prevents proper compression of the breast. The results suggest that the exact positioning of the MLO-projection should be carefully evaluated in order to find a balance between breast compression and tissue inclusion.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Breast
compression
mammography
positioning
pressure

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Dustler, Magnus
Andersson, Ingva ...
Förnvik, Daniel
Tingberg, Anders
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Radiologi och bi ...
Artiklar i publikationen
Medical Imaging ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy