Improved performance characteristics of the von Willebrand factor ristocetin cofactor activity assay using a novel automated assay protocol.

Hillarp, Andreas (författare)
Lund University,Lunds universitet,Klinisk kemi, Malmö,Forskargrupper vid Lunds universitet,Clinical Chemistry, Malmö,Lund University Research Groups
Stadler, M (författare)
Haderer, C (författare)
visa fler...
Weinberger, J (författare)
Kessler, C M (författare)
Römisch, J (författare)
visa färre...
 (creator_code:org_t)
Elsevier BV, 2010
2010
Engelska.
Ingår i: Journal of Thrombosis and Haemostasis. - : Elsevier BV. - 1538-7933 .- 1538-7836. ; 8, s. 2216-2223
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Summary Background, objectives and methods: An accurate, sensitive and precise assay for reliable determination of the ristocetin cofactor activity of von Willebrand factor (VWF:RCo) in plasma and von Willebrand Factor (VWF)-containing concentrates has been evaluated. The assay is based on a commercially available automated protocol with modifications including a combination of adding additional ristocetin and the use of two calibration curves for the high and low measuring ranges. Results: Addition of extra ristocetin resulted in improved measurement of VWF recoveries from various VWF-containing concentrates that were underestimated using the standard automated protocol. The modifications resulted in improved assay performance over an extended measuring range (2.00 - 0.03 IU/mL). Accuracy was tested using VWF deficiency plasma spiked with 1(st) international standard for VWF concentrate. Seven dilutions, ranging between 1.80 and 0.05 IU/mL, were analyzed and resulted in measured concentrations between 80% and 100% of the assigned potency of the standard. Linearity was determined from the regression plot of the same concentrate dilutions and resulted in a correlation coefficient of 0.998. The repeatability, expressed as coefficient of variation, was 2% in the normal range (0.90 IU/mL) and 8% at the level of 0.05 IU/mL. The corresponding reproducibility results were 2% and 15% at the normal and low measuring ranges, respectively. Conclusions: Analysis of patients with von Willebrand disease indicates that the modified automated BCS((R)) protocol has a superior discrimination power compared with the standard protocol. This is especially true in samples with low VWF, as in patients with type 3 von Willebrand disease.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kardiologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Cardiac and Cardiovascular Systems (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hillarp, Andreas
Stadler, M
Haderer, C
Weinberger, J
Kessler, C M
Römisch, J
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Kardiologi
Artiklar i publikationen
Journal of Throm ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy