SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rück A)
 

Sökning: WFRF:(Rück A) > (2010-2014) > Heart rate variabil...

  • Svensson, AKarolinska Institutet (författare)

Heart rate variability and heat sensation during CT coronary angiography: Low-osmolar versus iso-osmolar contrast media

  • Artikel/kapitelEngelska2010

Förlag, utgivningsår, omfång ...

  • 2010-09-01
  • SAGE Publications,2010

Nummerbeteckningar

  • LIBRIS-ID:oai:prod.swepub.kib.ki.se:121284724
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:121284724URI
  • https://doi.org/10.3109/02841851.2010.488249DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Background: During computed tomography coronary angiography (CTCA) unexpected changes in heart rate while scanning may affect image quality. Purpose: To evaluate whether an iso-osmolar contrast medium (IOCM, iodixanol) and a low-osmolar contrast medium (LOCM, iomeprol) affect heart rate and experienced heat sensation differently. Material and Methods: One hundred patients scheduled for CTCA were randomized to receive either iodixanol 320 mgI/ml or iomeprol 400 mgI/ml. Depending on their heart rate, the patients were assigned to one of five scanning protocols, each optimized for different heart rate ranges. During scanning the time between each heart beat (hb) was recorded, and the corresponding heart rate was calculated. For each contrast medium (CM) the average heart rate, the variation in heart rate from individual mean heart rate, and the mean deviation from the predefined scanning protocol were calculated. Experience of heat was obtained immediately after scanning by using a visual analog scale (VAS). Examination quality was rated by two radiologists on a three-point scale. Results: The mean variation in heart rate after IOCM was 1.4 hb/min and after LOCM it was 4.4 hb/min (NS). The mean deviations in heart rate from that in the predefined scanning protocol were 2.0 hb/min and 4.7 hb/min, respectively (NS). A greater number of arrhythmic hb were observed after LOCM compared with IOCM ( P<0.001). There was no statistically significant difference in image quality. The LOCM group reported a stronger heat sensation after CM injection than the IOCM group (VAS =36 mm and 18 mm, P<0.05). Conclusion: At clinically used concentrations the IOCM, iodixanol 320 mgI/ml, does not increase the heart rate during CTCA and causes less heart arrhythmia and less heat sensation than the LOCM, iomeprol 400 mgI/ml.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ripsweden, JKarolinska Institutet (författare)
  • Ruck, AKarolinska Institutet (författare)
  • Aspelin, PKarolinska Institutet (författare)
  • Cederlund, KKarolinska Institutet (författare)
  • Brismar, BTKarolinska Institutet (författare)
  • Karolinska Institutet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Acta radiologica (Stockholm, Sweden : 1987): SAGE Publications51:7, s. 722-7261600-04550284-1851

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy