Using GafChromic film to estimate the effective dose from dental cone beam CT and panoramic radiography

Al-Okshi, Ayman (author)
Malmö högskola,Odontologiska fakulteten (OD)
Nilsson, M. (author)
Malmö högskola,Odontologiska fakulteten (OD)
Petersson, A. (author)
Malmö högskola,Odontologiska fakulteten (OD)
show more...
Wiese, M. (author)
Lindh, Christina (author)
Malmö högskola,Odontologiska fakulteten (OD)
show less...
 (creator_code:org_t)
British Institute of Radiology, 2013
2013
English.
In: Dento-Maxillo-Facial Radiology. - : British Institute of Radiology. - 0250-832X .- 1476-542X. ; 42:7
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Objectives: To demonstrate the feasibility of GafChromic(®) XR-QA2 (ISP Corp., Wayne, NJ) as a dosemeter when performing measurements of the effective dose from three cone beam CT (CBCT) units and to compare the doses from examinations of three common dental clinical situations. A second aim was to compare the radiation doses for three digital panoramic units with the doses for the CBCT units. METHODS: The CBCT units used were Veraviewepocs 3De(®) (J Morita MFG Corp., Kyoto, Japan), ProMax(®) 3D (Planmeca, Helsinki, Finland) and NewTom VGi(®) (Quantitative Radiology, Verona, Italy). GafChromic XR-QA2 films were placed between the selected layers of the head and neck of a tissue-equivalent human skull (RANDO(®) phantom; The Phantom Laboratory, Salem, NY). The exposure parameters were set using the automatic exposure control function of the units. Depending on the availability, medium and smaller field of view (FOV) scanning modes were used. The effective dose was estimated using the 2007 International Commission on Radiological Protection formalism. RESULTS: The lowest effective dose of a CBCT unit was observed for ProMax 3D, FOV 4 × 5 cm (10 μSv), the highest for NewTom VGi, FOV 8 × 8 cm-high resolution (129 μSv). The range of effective doses for digital panoramic machines measured was 8-14 μSv. CONCLUSIONS: This study demonstrates the feasibility of using radiochromic films for dental CBCT and panoramic dosimetry.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Keyword

RADIATION DOSAGE
CONE BEAM COMPUTED TOMOGRAPHY
FILM DOSIMETRY

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Al-Okshi, Ayman
Nilsson, M.
Petersson, A.
Wiese, M.
Lindh, Christina
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Dentistry
Articles in the publication
Dento-Maxillo-Fa ...
By the university
Malmö University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view