A Measure of Septum Shape Using Shortest Path Segmentation in Echocardiographic Images of LVAD Patients
-
- Landgren, Matilda (författare)
- Lund University,Lunds universitet,Matematik LTH,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematics (Faculty of Engineering),Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Overgaard, Niels Christian (författare)
- Lund University,Lunds universitet,Matematik LTH,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematics (Faculty of Engineering),Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
-
- Heyden, Anders (författare)
- Lund University,Lunds universitet,Matematik LTH,Matematikcentrum,Institutioner vid LTH,Lunds Tekniska Högskola,Mathematics (Faculty of Engineering),Centre for Mathematical Sciences,Departments at LTH,Faculty of Engineering, LTH
-
(creator_code:org_t)
- 2014
- 2014
- Engelska 6 s.
-
Ingår i: Pattern Recognition (ICPR), 2014 22nd International Conference on. - 1051-4651. ; , s. 3398-3403
- Relaterad länk:
-
http://ieeexplore.ie...
-
visa fler...
-
http://dx.doi.org/10...
-
https://lup.lub.lu.s...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Patients waiting for heart transplantation due to a failing heart can get a left ventricular assist device (LVAD) implanted through open chest surgery. The device consists of a pump that pumps blood from the left ventricle into the aorta. To get the correct rotation speed of the pump, the physicians consider a number of measurements as well as a sequence of echocardiographic images. The important information obtained from the images is the shape of the inter-ventricular septum. For instance, if the septum bulges towards the left ventricle the speed is too high and it might harm the right ventricular function. To get a measure of the shape of the septum, which can be incorporated in a decision support system, we perform a segmentation of the septum using a shortest path method. To reduce user interaction, the user only needs to annotate two anchor points in the first frame. They mark the endpoints of the septum and they are tracked through the sequence with our tracking algorithm. After the segmentation the septum is divided into two regions, the one closest to the right ventricle and the one closest to the left ventricle, and the desired measure is the difference between the areas of these regions divided by the total septum area. The performance of the segmentation algorithm is acceptable and the obtained septum measure corresponds in most cases to the assessments from a physician.
Ämnesord
- NATURVETENSKAP -- Data- och informationsvetenskap -- Datorseende och robotik (hsv//swe)
- NATURAL SCIENCES -- Computer and Information Sciences -- Computer Vision and Robotics (hsv//eng)
- NATURVETENSKAP -- Matematik (hsv//swe)
- NATURAL SCIENCES -- Mathematics (hsv//eng)
Publikations- och innehållstyp
- kon (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas