SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Martensson L.)
 

Search: WFRF:(Martensson L.) > Assessing TEG6S rel...

Assessing TEG6S reliability between devices and across multiple time points: A prospective thromboelastography validation study

Lloyd-Donald, P (author)
Churilov, L (author)
Cheong, B (author)
show more...
Bellomo, R (author)
McCall, PR (author)
Martensson, J (author)
Karolinska Institutet
Glassford, N (author)
Weinberg, L (author)
show less...
 (creator_code:org_t)
2020-04-27
2020
English.
In: Scientific reports. - : Springer Science and Business Media LLC. - 2045-2322. ; 10:1, s. 7045-
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The TEG6S is a novel haemostasis analyser utilising resonance technology. It offers potentially greater coagulation information and ease of use, however has not been independently validated in a clinical setting. We aimed to determine if the TEG6S is reliable between devices and across time points. We performed a prospective observational study with ethical approval. For interdevice reliability, we performed simultaneous analysis on two TEG6S devices on 25 adult ICU patients. For time point reliability, we performed repeated sampling across five different time points on 15 adult participants. Blood was collected with informed consent, or as standard care, before four-channel citrated kaolin analysis. We observed almost perfect interdevice reliability across all TEG parameters. The Lin’s concordance correlation coefficients (95% CI, major axis regression slope, intercept) were R-time: 0.96 (0.92–0.99, 0.88, 0.57); K-time: 0.93 (0.87–0.98, 1.07, 0.00); Alpha Angle: 0.87 (0.78–0.96, 1.20, −14.10); Maximum Amplitude: 0.99 (0.98–0.99, 1.02, −1.38); Clot Lysis: 0.89 (0.82–0.97, 1.20, 0.07). Additionally, we observed moderate-to-high reliability across time points. Demonstrating almost perfect agreement across different devices and moderate-to-high reliability across multiple time points, suggests the TEG6S platform can be used with haemostatic accuracy and generalisability. This has potentially significant implications for clinical practice and multi-site research programs.

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view