SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sill B)
 

Sökning: WFRF:(Sill B) > Display evaluation ...

  • Clarke, Emily L.Univ Leeds, England; Leeds Teaching Hosp NHS Trust, England (författare)

Display evaluation for primary diagnosis using digital pathology

  • Artikel/kapitelEngelska2020

Förlag, utgivningsår, omfång ...

  • SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS,2020
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-171816
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-171816URI
  • https://doi.org/10.1117/1.JMI.7.2.027501DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Funding Agencies|Data to Early Diagnosis and Precision Medicine Strand of the Governments Industrial Strategy Challenge Fund [104687]
  • Purpose: As pathology departments around the world contemplate digital microscopy for primary diagnosis, making an informed choice regarding display procurement is very challenging in the absence of defined minimum standards. In order to help inform the decision, we aimed to conduct an evaluation of displays with a range of technical specifications and sizes. Approach: We invited histopathologists within our institution to take part in a survey evaluation of eight short-listed displays. Pathologists reviewed a single haematoxylin and eosin whole slide image of a benign nevus on each display and gave a single score to indicate their preference in terms of image quality and size of the display. Results: Thirty-four pathologists took part in the display evaluation experiment. The preferred display was the largest and had the highest technical specifications (11.8-MP resolution, 2100 cd/m(2) maximum luminance). The least preferred display had the lowest technical specifications (2.3-MP resolution, 300 cd/m(2) maximum luminance). A trend was observed toward an increased preference for displays with increased luminance and resolution. Conclusions: This experiment demonstrates a preference for large medical-grade displays with the high luminance and high resolution. As cost becomes implicated in procurement, significantly less expensive medical-grade displays with slightly lower technical specifications may be the most cost-effective option. (C) 2020 Society of Photo-Optical Instrumentation Engineers (SPIE)

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Munnings, CraigLeeds Teaching Hosp NHS Trust, England (författare)
  • Williams, BethanyUniv Leeds, England; Leeds Teaching Hosp NHS Trust, England (författare)
  • Brettle, DavidLeeds Teaching Hosp NHS Trust, England (författare)
  • Treanor, DarrenLinköpings universitet,Avdelningen för inflammation och infektion,Medicinska fakulteten,Region Östergötland, Klinisk patologi,Univ Leeds, England; Leeds Teaching Hosp NHS Trust, England(Swepub:liu)dartr72 (författare)
  • Univ Leeds, England; Leeds Teaching Hosp NHS Trust, EnglandLeeds Teaching Hosp NHS Trust, England (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Journal of Medical Imaging: SPIE-SOC PHOTO-OPTICAL INSTRUMENTATION ENGINEERS7:22329-43022329-4310

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy