SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:prod.swepub.kib.ki.se:144255673"
 

Sökning: onr:"swepub:oai:prod.swepub.kib.ki.se:144255673" > Towards Optical Ima...

  • Manni, F (författare)

Towards Optical Imaging for Spine Tracking without Markers in Navigated Spine Surgery

  • Artikel/kapitelEngelska2020

Förlag, utgivningsår, omfång ...

  • 2020-06-29
  • MDPI AG,2020

Nummerbeteckningar

  • LIBRIS-ID:oai:prod.swepub.kib.ki.se:144255673
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:144255673URI
  • https://doi.org/10.3390/s20133641DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Surgical navigation systems are increasingly used for complex spine procedures to avoid neurovascular injuries and minimize the risk for reoperations. Accurate patient tracking is one of the prerequisites for optimal motion compensation and navigation. Most current optical tracking systems use dynamic reference frames (DRFs) attached to the spine, for patient movement tracking. However, the spine itself is subject to intrinsic movements which can impact the accuracy of the navigation system. In this study, we aimed to detect the actual patient spine features in different image views captured by optical cameras, in an augmented reality surgical navigation (ARSN) system. Using optical images from open spinal surgery cases, acquired by two gray-scale cameras, spinal landmarks were identified and matched in different camera views. A computer vision framework was created for preprocessing of the spine images, detecting and matching local invariant image regions. We compared four feature detection algorithms, Speeded Up Robust Feature (SURF), Maximal Stable Extremal Region (MSER), Features from Accelerated Segment Test (FAST), and Oriented FAST and Rotated BRIEF (ORB) to elucidate the best approach. The framework was validated in 23 patients and the 3D triangulation error of the matched features was < 0.5 mm. Thus, the findings indicate that spine feature detection can be used for accurate tracking in navigated surgery.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Elmi-Terander, AKarolinska Institutet (författare)
  • Burstrom, GKarolinska Institutet (författare)
  • Persson, OKarolinska Institutet (författare)
  • Edstrom, EKarolinska Institutet (författare)
  • Holthuizen, R (författare)
  • Shan, C (författare)
  • Zinger, S (författare)
  • van der Sommen, F (författare)
  • de With, PHN (författare)
  • Karolinska Institutet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Sensors (Basel, Switzerland): MDPI AG20:131424-8220

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy