SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Killick E)
 

Sökning: WFRF:(Killick E) > Deep learning nucle...

Deep learning nuclei detection: A simple approach can deliver state-of-the-art results

Hoefener, Henning (författare)
Fraunhofer MEVIS, Germany
Homeyer, Andre (författare)
Fraunhofer MEVIS, Germany
Weiss, Nick (författare)
Fraunhofer MEVIS, Germany
visa fler...
Molin, Jesper (författare)
Sectra AB, Teknikringen 20, S-58330 Linkoping, Sweden
Lundström, Claes (författare)
Linköpings universitet,Medie- och Informationsteknik,Tekniska fakulteten,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Sectra AB, Teknikringen 20, S-58330 Linkoping, Sweden
Hahn, Horst K. (författare)
Fraunhofer MEVIS, Germany; Jacobs Univ, Germany
visa färre...
 (creator_code:org_t)
PERGAMON-ELSEVIER SCIENCE LTD, 2018
2018
Engelska.
Ingår i: Computerized Medical Imaging and Graphics. - : PERGAMON-ELSEVIER SCIENCE LTD. - 0895-6111 .- 1879-0771. ; 70, s. 43-52
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Deep convolutional neural networks have become a widespread tool for the detection of nuclei in histopathology images. Many implementations share a basic approach that includes generation of an intermediate map indicating the presence of a nucleus center, which we refer to as PMap. Nevertheless, these implementations often still differ in several parameters, resulting in different detection qualities. Methods: We identified several essential parameters and configured the basic PMap approach using combinations of them. We thoroughly evaluated and compared various configurations on multiple datasets with respect to detection quality, efficiency and training effort. Results: Post-processing of the PMap was found to have the largest impact on detection quality. Also, two different network architectures were identified that improve either detection quality or runtime performance. The best-performing configuration yields f1-measures of 0.816 on Hamp;E stained images of colorectal adenocarcinomas and 0.819 on Ki-67 stained images of breast tumor tissue. On average, it was fully trained in less than 15,000 iterations and processed 4.15 megapixels per second at prediction time. Conclusions: The basic PMap approach is greatly affected by certain parameters. Our evaluation provides guidance on their impact and best settings. When configured properly, this simple and efficient approach can yield equal detection quality as more complex and time-consuming state-of-the-art approaches. (C) 2018 The Authors. Published by Elsevier Ltd.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk bildbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Image Processing (hsv//eng)

Nyckelord

Nuclei detection; Deep learning; PMap; Histology; Image analysis

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy