SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thurston C)
 

Sökning: WFRF:(Thurston C) > Validity of Hip and...

  • Bezuidenhout, LKarolinska Institutet (författare)

Validity of Hip and Ankle Worn Actigraph Accelerometers for Measuring Steps as a Function of Gait Speed during Steady State Walking and Continuous Turning

  • Artikel/kapitelEngelska2021

Förlag, utgivningsår, omfång ...

  • 2021-05-01
  • MDPI AG,2021

Nummerbeteckningar

  • LIBRIS-ID:oai:prod.swepub.kib.ki.se:146614551
  • http://kipublications.ki.se/Default.aspx?queryparsed=id:146614551URI
  • https://doi.org/10.3390/s21093154DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • This study aimed to investigate the accuracy and reliability of hip and ankle worn Actigraph GT3X+ (AG) accelerometers to measure steps as a function of gait speed. Additionally, the effect of the low frequency extension filter (LFEF) on the step accuracy was determined. Thirty healthy individuals walked straight and walked with continuous turns in different gait speeds. Number of steps were recorded with a hip and ankle worn AG, and with a Stepwatch (SW) activity monitor positioned around the right ankle, which was used as a reference for step count. The percentage agreement, interclass correlation coefficients and Bland–Altmann plots were determined between the AG and the reference SW across gait speeds for the two walking conditions. The ankle worn AG with the default filter was the most sensitive for step detection at >0.6 m/s, whilst accurate step detection for gait speeds < 0.6 m/s were only observed when applying the LFEF. The hip worn AG with the default filter showed poor accuracy (12–78%) at gait speeds < 1.0 m/s whereas the accuracy increased to >87% for gait speeds < 1.0 m/s when applying the LFEF. Ankle worn AG was the most sensitive to measure steps at a vast range of gait speeds. Our results suggest that sensor placement and filter settings need to be taken into account to provide accurate estimates of step counts.

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Thurston, CKarolinska Institutet (författare)
  • Hagstromer, MKarolinska Institutet (författare)
  • Conradsson, DMKarolinska Institutet (författare)
  • Karolinska Institutet (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Sensors (Basel, Switzerland): MDPI AG21:91424-8220

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bezuidenhout, L
Thurston, C
Hagstromer, M
Conradsson, DM
Artiklar i publikationen
Sensors (Basel, ...
Av lärosätet
Karolinska Institutet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy