Influence of CBCT-based volumetric distortion and beam hardening artefacts on the assessment of root canal filling quality in isthmus-containing molars

Rodrigues, CT (författare)
Jacobs, R (författare)
Karolinska Institutet
Vasconcelos, KF (författare)
visa fler...
Lambrechts, P (författare)
Rubira-Bullen, IRF (författare)
Gaeta-Araujo, H (författare)
Oliveira-Santos, C (författare)
Duarte, MAH (författare)
visa färre...
 (creator_code:org_t)
British Institute of Radiology, 2021
2021
Engelska.
Ingår i: Dento maxillo facial radiology. - : British Institute of Radiology. - 0250-832X. ; 50:5, s. 20200503-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To evaluate the influence of artefacts in cone beam CT (CBCT) images of filled root canals in isthmus-containing molars.Methods:10 teeth presenting canals with an isthmus were instrumented and filled with a thermoplasticised obturation technique. The teeth were scanned using a micro-CT device and two CBCT devices: 3D Accuitomo 170 (ACC) and NewTom VGi evo (NT), with different acquisition protocols: larger and smaller voxel size. Three examiners assessed the CBCT images for: (1) detection of filling voids; (2) assessment of under- or overestimation of the filling material and (3) resemblance of CBCT images to the reference standard. Analyses of Task 1 yielded accuracy, sensitivity and specificity for detection of filling voids. For tasks 2 and 3, statistical analysis was performed using Wilcoxon test. The level of significance was set at p < .05.Results:For Task 1, ACC showed higher sensitivity, whereas NT presented higher specificity. No significant difference was found between the protocols in ACC, however, for NT, differences between protocols were significant for all diagnostic values. In Task 2, visualisation of the filling was overestimated for NT, while for ACC, underestimation was observed. For Task 3, images with smaller voxel size were more similar to the reference image, for both CBCT devices.Conclusions:Different artefacts compromise the detection of filling voids on CBCT images of canals in mandibular molars with isthmus. ACC and NT present rather similar diagnostic accuracy, even though artefact expression remains device-specific.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy