SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Lucassen M.)
 

Sökning: WFRF:(Lucassen M.) > Identifying clot co...

Identifying clot composition using intravascular diffuse reflectance spectroscopy in a porcine model of endovascular thrombectomy

Skyrman, S (författare)
Burstrom, G (författare)
Karolinska Institutet
Aspegren, O (författare)
Karolinska Institutet
visa fler...
Lucassen, G (författare)
Elmi-Terander, A (författare)
Karolinska Institutet
Edstrom, E (författare)
Karolinska Institutet
Arnberg, F (författare)
Karolinska Institutet
Ohlsson, M (författare)
Karolinska Institutet
Mueller, M (författare)
Andersson, T (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
2021-04-15
2022
Engelska.
Ingår i: Journal of neurointerventional surgery. - : BMJ. - 1759-8486 .- 1759-8478. ; 14:3, s. 304-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Endovascular thrombectomy has revolutionized the management of acute ischemic stroke and proven superior to stand-alone intravenous thrombolysis for large vessel occlusions. However, failed or delayed revascularization may occur as a result of a mismatch between removal technique and clot composition. Determination of clot composition before thrombectomy provides the possibility to adapt the technique to improve clot removal efficacy. We evaluated the application of diffuse reflectance spectroscopy (DRS) for intravascular determination of clot composition in vivo.MethodsThree clot types, enriched in red blood cells or fibrin or with a mixed content, were prepared from porcine blood and injected into the external carotids of a domestic pig. A guidewire-like DRS probe was used to investigate the optical spectra of clots, blood and vessel wall. Measurement positions were confirmed with angiography. Spectra were analyzed by fitting an optical model to derive physiological parameters. To evaluate the method’s accuracy, photon scattering and blood and methemoglobin contents were included in a decision tree model and a random forest classification.ResultsDRS could differentiate between the three different clot types, blood and vessel wall in vivo (p<0.0001). The sensitivity and specificity for detection was 73.8% and 98.8% for red blood cell clots, 80.6% and 97.8% for fibrin clots, and 100% and 100% for mixed clots, respectively.ConclusionIntravascular DRS applied via a custom guidewire can be used for reliable determination of clot composition in vivo. This novel approach has the potential to increase efficacy of thrombectomy procedures in ischemic stroke.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy