CTmod : a toolkit for Monte Carlo simulation of projections including scatter in computed tomography

  • Artikel/kapitelEngelska2008

Förlag, utgivningsår, omfång ...

  • Elsevier,2008
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-13035
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-13035URI
  • https://doi.org/10.1016/j.cmpb.2007.12.005DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Original Publication: Alexandr Malusek, Michael Sandborg and Gudrun Alm Carlsson, CTmod: a toolkit for Monte Carlo simulation of projections including scatter in computed tomography, 2008, Computer Methods and Programs in Biomedicine, (90), 2, 167-178. http://dx.doi.org/10.1016/j.cmpb.2007.12.005 Copyright: Elsevier Science B.V., Amsterdam. http://www.elsevier.com/
  • The CTmod toolkit is a set of C++ class libraries based on the CERN’s application development framework ROOT. It uses the Monte Carlo method to simulate energy imparted to a CT-scanner detector array. Photons with a given angle–energy distribution are emitted from the X-ray tube approximated by a point source, transported through a phantom, and their contribution to the energy imparted per unit surface area of each detector element is scored. Alternatively, the scored quantity may be the fluence, energy fluence, plane fluence, plane energy fluence, or kerma to air in the center of each detector element. Phantoms are constructed from homogenous solids or voxel arrays via overlapping. Implemented photon interactions (photoelectric effect, coherent scattering, and incoherent scattering) are restricted to the energy range from 10 to 200 keV. Variance reduction techniques include the collision density estimator and survival biasing combined with the Russian roulette. The toolkit has been used to estimate the amount of scatter in cone beam computed tomography and planar radiography.

Ämnesord och genrebeteckningar

  • Monte Carlo
  • Computed tomography
  • Cone beam
  • Scatter
  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Sandborg, MichaelÖstergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen US(Swepub:liu)micsa02 (författare)
  • Alm Carlsson, GudrunLinköpings universitet,Medicinsk radiofysik,Hälsouniversitetet(Swepub:liu)gudal03 (författare)
  • Linköpings universitetMedicinsk radiofysik (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Computer Methods and Programs in Biomedicine: Elsevier90:2, s. 167-1780169-26071872-7565

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy