SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Verbanck S)
 

Sökning: WFRF:(Verbanck S) > Pulmonary tissue vo...

Pulmonary tissue volume, cardiac output, and diffusing capacity in sustained microgravity

Verbanck, S (författare)
Larsson, H (författare)
Karolinska Institutet
Linnarsson, D (författare)
Karolinska Institutet
visa fler...
Prisk, GK (författare)
West, JB (författare)
Paiva, M (författare)
visa färre...
 (creator_code:org_t)
American Physiological Society, 1997
1997
Engelska.
Ingår i: Journal of applied physiology (Bethesda, Md. : 1985). - : American Physiological Society. - 8750-7587 .- 1522-1601. ; 83:3, s. 810-816
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Verbanck, Sylvia, Hans Larsson, Dag Linnarsson, G. Kim Prisk, John B. West, and Manuel Paiva. Pulmonary tissue volume, cardiac output and diffusing capacity in sustained microgravity. J. Appl. Physiol. 83(3): 810–816, 1997.—In microgravity (μG) humans have marked changes in body fluids, with a combination of an overall fluid loss and a redistribution of fluids in the cranial direction. We investigated whether interstitial pulmonary edema develops as a result of a headward fluid shift or whether pulmonary tissue fluid volume is reduced as a result of the overall loss of body fluid. We measured pulmonary tissue volume (Vti), capillary blood flow, and diffusing capacity in four subjects before, during, and after 10 days of exposure to μG during spaceflight. Measurements were made by rebreathing a gas mixture containing small amounts of acetylene, carbon monoxide, and argon. Measurements made early in flight in two subjects showed no change in Vti despite large increases in stroke volume (40%) and diffusing capacity (13%) consistent with increased pulmonary capillary blood volume. Late in-flight measurements in four subjects showed a 25% reduction in Vti compared with preflight controls ( P < 0.001). There was a concomittant reduction in stroke volume, to the extent that it was no longer significantly different from preflight control. Diffusing capacity remained elevated (11%; P< 0.05) late in flight. These findings suggest that, despite increased pulmonary perfusion and pulmonary capillary blood volume, interstitial pulmonary edema does not result from exposure to μG.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy