SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Creswell J)
 

Sökning: WFRF:(Creswell J) > Pooling sputum for ...

Pooling sputum for Xpert MTB/RIF and Xpert Ultra testing during the Covid-19 pandemic in Lao People's Democratic Republic

Iem, V (författare)
Chittamany, P (författare)
Suthepmany, S (författare)
visa fler...
Siphanthong, S (författare)
Somphavong, S (författare)
Kontogianni, K (författare)
Dodd, J (författare)
Khan, JAM (författare)
Dominguez, J (författare)
Wingfield, T (författare)
Karolinska Institutet
Creswell, J (författare)
Cuevas, LE (författare)
visa färre...
 (creator_code:org_t)
2022-04-04
2022
Engelska.
Ingår i: PLOS global public health. - : Public Library of Science (PLoS). - 2767-3375. ; 2:4, s. e0000116-
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The global Covid-19 pandemic has limited access to molecular TB diagnostics and National Programmes are struggling to maintain essential services. The pooling method (testing several samples together) could reduce the number of cartridges and staff time needed for TB diagnosis but has not been tested within the pandemic. We conducted two independent cross-sectional surveys. Pools composed of four sputum samples were tested using either Xpert-MTB/RIF or Xpert-Ultra. Pooled and individual results were compared to determine the level of agreement. Each survey included 840 participants and 210 pools. In the Xpert MTB/RIF survey, 77/81 (sensitivity 95.1%, 95%CI 87.8%-98.6%) pools containing ≥1 positive sample tested MTB-positive and 4/81 (4.9%, 95%CI 1.4%-12.2%) tested MTB-negative. All 129/129 pools containing MTB-negative samples tested MTB-negative (specificity 100%, 95%CI 97.2%-100%), with 98.1% agreement (Kappa: 0.959). In the Xpert-Ultra survey, 70/70 (sensitivity 100%, 95%CI 94.9%-100%) pools containing ≥ 1 MTB-positive sample tested MTB-positive and 140/140 (specificity 100%, 95%CI 97.4%-100%) pools containing only MTB-negative samples tested MTB-negative, with 100% agreement (Kappa: 1). Pooled testing with Xpert-MTB/RIF and Xpert-Ultra saved 38.3% and 41.7% (322/840 and 350/840, respectively) in cartridge costs alone. The pooling method with Xpert-MTB/RIF and Xpert-Ultra has similar performance to individual testing and can reduce the number of cartridges needed. These efficiencies can facilitate maintenance of stocks and sustain essential services as countries face difficulties for laboratory procurement during the pandemic and will provide cost and time savings post-pandemic.

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy