SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Samuelsson Ola)
 

Sökning: WFRF:(Samuelsson Ola) > (2015-2019) > Conceptual Mean-lin...

Conceptual Mean-line Design of a Low Pressure Turbine for a Geared Turbofan with Rear Structure Interaction

Zhao, Xin, 1986 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Raja, Visakha, 1985 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Samuelsson, Sebastian, 1987 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Isaksson, Ola, 1969 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Lundbladh, Anders, 1964 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Grönstedt, Tomas, 1970 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2019
2019
Engelska.
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • One of the most important features of a geared turbofan (GTF) is a reduced number of low pressure turbine (LPT) stages resulting from a faster spinning spool. Compared to a direct drive turbofan (DDTF), in which the LPT normally constitutes a considerable part of the engine total weight, from 10% to more than 25%, dependent on the engine bypass ratio (BPR), fewer stages can cut the weight into half or even less for the LPT. With this benefit, the weight of the LPT alone is no longer a dominating factor for the selection of its configuration. To obtain an optimal LPT configuration for a GTF requires a new balance between weight and performance involving both the LPT and the downstream component, the turbine rear structure (TRS). A conceptual design of the LPT for a mid- to long-range GTF is presented here to clarify this new balance. By comparing a range of designs based on different number of stages and turbine hade angles, the selection of the LPT design for the GTF is described. More importantly, interactions between the LPT design and the TRS design are considered. Results indicate that a joint design is necessary as the TRS plays an important role in designing the LPT of a GTF. It is shown that if the LPT design is done in isolation from the TRS design, a 3-stage LPT performs better than a 4-stage design from a fuel burn perspective. However, when the TRS design is considered, the advantage of the 3-stage LPT design is offset by the associated TRS weight and loss increase, compared to the 4-stage LPT design.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Rymd- och flygteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Aerospace Engineering (hsv//eng)

Nyckelord

parametric study
design for performance
low pressure turbine
conceptual design
geared turbofan
turbine rear structure

Publikations- och innehållstyp

kon (ämneskategori)
vet (ämneskategori)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy