SwePub
Sök i LIBRIS databas

  Utökad sökning

AMNE:(TEKNIK OCH TEKNOLOGIER) AMNE:(Naturresursteknik) AMNE:(Fjärranalysteknik)
 

Sökning: AMNE:(TEKNIK OCH TEKNOLOGIER) AMNE:(Naturresursteknik) AMNE:(Fjärranalysteknik) > Optical Tolerance A...

Optical Tolerance Analysis of the Multi-Beam Limb Viewing Instrument STEAMR

Hammar, Arvid, 1986 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Whale, Mark, 1983 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Forsberg, Per (författare)
Omnisys Instruments AB
visa fler...
Murk, Axel (författare)
Universität Bern,University of Bern
Emrich, Anders, 1962 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Stake, Jan, 1971 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2014
2014
Engelska.
Ingår i: IEEE Transactions on Terahertz Science and Technology. - 2156-342X .- 2156-3446. ; 4:6, s. 714-721
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We report on an optical tolerance analysis of the submillimeter atmospheric multi-beam limb sounder STEAMR. Physical optics and ray-tracing methods were used to quantify and separate errors in beam pointing and distortion due to reflector misalignment and primary reflector surface deforma-tions. Simulations were performed concurrently with the man-ufacturing of a multi-beam demonstrator of the relay optical system which shapes and images the beams to their corresponding receiver feed horns. Results from Monte-Carlo simulations show that the inserts used for reflector mounting should be positioned with an overall accuracy better than 100 µm (~1/10 wavelength). Analyses of primary reflector surface deformations show that a deviation of magnitude 100 µm can be tolerable before deployment, whereas the corresponding variations should be less than 30 µm during operation. The most sensitive optical elements in terms of misalignments are found near the focal plane. This localized sensitivity is attributed to the off-axis nature of the beams at this location. Post-assembly mechanical measurements of the reflectors in the demonstrator show that alignment better than 50 µm could be obtained.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Fjärranalysteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Remote Sensing (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Annan naturresursteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Other Environmental Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

STEAMR
quasi-optics
submillimeter wave instruments
limb viewing
Monte-Carlo
multi-beam
tolerance analysis

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy