SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Forsman Mikael Professor)
 

Sökning: WFRF:(Forsman Mikael Professor) > Mind the gap – deve...

Mind the gap – development of conversion models between accelerometer- and IMU-based measurements of arm and trunk postures and movements in warehouse work

Forsman, Mikael, Professor (författare)
KTH,Ergonomi,IMM Institute of Environmental Medicine, Karolinska Institutet, Stockholm, SE-171 77, Sweden; Centre for Occupational and Environmental Medicine, Stockholm County Council, Stockholm, SE-113 65, Sweden,Stockholms läns landsting,Stockholm County Council,Karolinska Institutet,Kungliga Tekniska Högskolan (KTH),Royal Institute of Technology (KTH)
Fan, Xuelong (författare)
Karolinska Institutet
Rhen, Ida-Märta, 1975 (författare)
Karolinska Institutet
visa fler...
Lind, Carl Mikael (författare)
Karolinska Institutet
visa färre...
 (creator_code:org_t)
Elsevier BV, 2022
2022
Engelska.
Ingår i: Applied Ergonomics. - : Elsevier BV. - 0003-6870 .- 1872-9126. ; 105
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Sensor type (accelerometers only versus inertial measurement units, IMUs) and angular velocity computational method (inclination versus generalized velocity) have been shown to affect the measurements of arm and trunk movements. This study developed models for conversions between accelerometer and IMU measurements of arm and trunk inclination and between accelerometer and IMU measurements of inclination and generalized (arm) velocities. Full-workday recordings from accelerometers and IMUs of arm and trunk postures and movements from 38 warehouse workers were used to develop 4 angular (posture) and 24 angular velocity (movement) conversion models for the distributions of the data. A power function with one coefficient and one exponent was used, and it correlated well (r2 > 0.999) in all cases to the average curves comparing one measurement with another. These conversion models facilitate the comparison and merging of measurements of arm and trunk movements collected using the two sensor types and the two computational methods.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Havs- och vattendragsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Ocean and River Engineering (hsv//eng)

Nyckelord

Sensor conversion
Field measurement
Inertial measurement unit

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy