SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:research.chalmers.se:5346aea8-93d1-4ffc-b1dd-deb01285d008"
 

Sökning: id:"swepub:oai:research.chalmers.se:5346aea8-93d1-4ffc-b1dd-deb01285d008" > Ultrasound Image An...

  • Holdfeldt, Peter,1976Chalmers tekniska högskola,Chalmers University of Technology (författare)

Ultrasound Image Analysis for Automated Classification of Atherosclerotic Plaque in the Human Carotid Artery

  • BokEngelska2007

Förlag, utgivningsår, omfång ...

  • 2007

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:5346aea8-93d1-4ffc-b1dd-deb01285d008
  • https://research.chalmers.se/publication/42744URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:lic swepub-publicationtype
  • Ämneskategori:vet swepub-contenttype

Anmärkningar

  • Cardiovascular diseases, caused by atherosclerosis, is one of the most common causes of death in the industrialized world. Two risk factors, that both can be assessed with ultrasound, are the Intima-Media Thickness (IMT) in the arterial wall and the composition of the atherosclerotic plaque. Plaques can be classied according to the subjective Gray-Weale scale. Its four classes are based on the echogenicity of the plaque, where class 1 is the most echolucent class and class 4 the most echogenic. In this thesis class 1 and 2 are merged into an echolucent class, and class 3 and 4 into an echogenic class. The motivation for this grouping is the fact that echolucent plaques are more unstable, and therefore more dangerous, than echogenic plaques. An automatic classication based on thresholding the plaque with an adaptive threshold has been developed. The threshold is a weighted sum of the echogenecity and the noise in the image, and it divides the plaque into black (echolucent) and white(echogenic) regions. The classication rate on the training set was 95% (92 of 97) when using leave-one-out crossvalidation, while the performance on the validation set was 91% (81 of 89). This thesis also contains a description of a computer program for automatic measurements of the IMT. An automatic system decreases both the analysis time and the interobserver variability compared to a manual system.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Chalmers tekniska högskola (creator_code:org_t)

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Holdfeldt, Peter ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy