SwePub
Tyck till om SwePub Sök här!
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wang Li San)
 

Sökning: WFRF:(Wang Li San) > Chalmers tekniska högskola > Design of Minimum C...

  • Li, Yang,1984Wuhan University of Technology (författare)

Design of Minimum Cost Degradation-Conscious Lithium-Ion Battery Energy Storage System to Achieve Renewable Power Dispatchability

  • Artikel/kapitelEngelska2020

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2020
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:5a48f9c2-2195-4461-8857-79e60c5583c9
  • https://doi.org/10.1016/j.apenergy.2019.114282DOI
  • https://research.chalmers.se/publication/520089URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • The application of lithium-ion (Li-ion) battery energy storage system (BESS) to achieve the dispatchability of a renewable power plant is examined. By taking into consideration the effects of battery cell degradation evaluated using electrochemical principles, a power flow model (PFM) of the BESS is developed specifically for use in system-level study. The PFM allows the long-term performance and lifetime of the battery be predicted as when the BESS is undertaking the power dispatch control task. Furthermore, a binary mode BESS control scheme is proposed to prevent the possible over-charge/over-discharge of the BESS due to the uncertain renewable input power. Analysis of the resulting new dispatch control scheme shows that a proposed adaptive BESS state of energy controller can guarantee the stability of the dispatch process. A particle swarm optimization algorithm is developed and is incorporated into a computational procedure for which the optimum battery capacity and power rating are determined, through minimizing the capital cost of the BESS plus the penalty cost of violating the dispatch power commitment. Results of numerical examples used to illustrate the proposed design approach show that in order to achieve hourly-constant power dispatchability of a 100-MW wind farm, the minimum-cost Li-ion BESS is rated 31-MW/22.6-MWh.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Vilathgamuwa, D. MahindaQueensland University of Technology (QUT) (författare)
  • Choi, San ShingQueensland University of Technology (QUT) (författare)
  • Xiong, BinyuWuhan University of Technology (författare)
  • Tang, JinruiWuhan University of Technology (författare)
  • Su, YixinWuhan University of Technology (författare)
  • Wang, YuNanyang Technological University (författare)
  • Wuhan University of TechnologyQueensland University of Technology (QUT) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Applied Energy: Elsevier BV2601872-91180306-2619

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy