SwePub
Sök i LIBRIS databas

  Utökad sökning

L4X0:1742 6588
 

Sökning: L4X0:1742 6588 > (2010-2014) > AD5933-based Spectr...

AD5933-based Spectrometer for Electrical Bioimpedance Applications

Ferreira, Javier, 1982- (författare)
Högskolan i Borås,Institutionen Ingenjörshögskolan
Seoane Martinez, Fernando, 1976 (författare)
Högskolan i Borås,Institutionen Ingenjörshögskolan
Ansede, Antonio (författare)
Universitat Politecnica de Catalunya,Polytechnic University of Catalonia,Högskolan i Borås,University of Borås,Technical University of Catalonia,Department of Electronic Engineering
visa fler...
bragos, Ramon (författare)
Universitat Politecnica de Catalunya,Polytechnic University of Catalonia,Technical University of Catalonia,Department of Electronic Engineering
visa färre...
 (creator_code:org_t)
2010-05-19
2010
Engelska.
Serie: Journal of Physics: Conference Series, 1742-6588
Ingår i: Journal of Physics: Conference Series. - : IOP Publishing. - 1742-6596. ; 224:1, s. 012011-
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • o build an Electrical Bioimpedance (EBI) spectrometer using the Impedance Measurement System-On-Chip AD5933 together with a 4-Electrode Analog Front End (4E-AFE) has been proven practicable. Such small measurement devices can make possible several new applications of EBI technology, especially when combined with functional textiles, which can enable wearable applications for personal health and home monitoring. After the implementation and functional validation of the 4E-AFE-enabled spectrometer, the next natural step is to validate for which EBI applications the 4E-AFE-enabled system is suitable. To test the applicability of this novel spectrometer on several EBI applications, 2R1C equivalent models have been experimentally obtained and impedance spectroscopy measurements have been performed with the system under study and with the SFB7 EBI spectrometer manufactured by ImpediMed. The 2R1C circuit parameters have been estimated with the BioImp software from the spectra obtained with both EBI spectrometers and the estimated values have been compared with the original values used in each circuit model implementation. The obtained results indicated that the 4E-AFE-enabled system cannot beat the performance of the SFB7 in accuracy but it performs better in preciseness. In any case the overall performance indicates that the 4E-AFE-enabled system can perform spectroscopy measurements in the frequency range from 5 to 100 kHz.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Medicinsk bioteknologi -- Biomedicinsk laboratorievetenskap/teknologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Medical Biotechnology -- Biomedical Laboratory Science/Technology (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

portable systems
Instrumentation
Bluetooth
Impedance spectroscopy

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy