  • Romano, FrancescoPolitecnico di Milano,Polytechnic University of Milan (författare)

Electrosurgical Smoke: Ultrafine Particle Measurements and Work Environment Quality in Different Operating Theatres

  • Artikel/kapitelEngelska2017

Förlag, utgivningsår, omfång ...

  • 2017-01-30
  • MDPI AG,2017
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:7598edd7-69c5-4d42-8ee0-0d69e7fcd19f
  • https://research.chalmers.se/publication/248026URI
  • https://doi.org/10.3390/ijerph14020137DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Air cleanliness in operating theatres (OTs) is an important factor for preserving the health of both the patient and the medical staff. Particle contamination in OTs depends mainly on the surgery process, ventilation principle, personnel clothing systems and working routines. In many open surgical operations, electrosurgical tools (ESTs) are used for tissue cauterization. ESTs generate a significant airborne contamination, as surgical smoke. Surgical smoke is a work environment quality problem. Ordinary surgical masks and OT ventilation systems are inadequate to control this problem. This research work is based on numerous monitoring campaigns of ultrafine particle concentrations in OTs, equipped with upward displacement ventilation or with a downward unidirectional airflow system. Measurements performed during ten real surgeries highlight that the use of ESTs generates a quite sharp and relevant increase of particle concentration in the surgical area as well within the entire OT area. The measured contamination level in the OTs are linked to surgical operation, ventilation principle, and ESTs used. A better knowledge of airborne contamination is crucial for limiting the personnel’s exposure to surgical smoke. Research results highlight that downward unidirectional OTs can give better conditions for adequate ventilation and contaminant removal performances than OTs equipped with upward displacement ventilation systems.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Gusten, Jan,1952Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)guste (författare)
  • Antonellis, Stefano DePolitecnico di Milano,Polytechnic University of Milan (författare)
  • Joppolo, Cesare M.Politecnico di Milano,Polytechnic University of Milan (författare)
  • Politecnico di MilanoChalmers tekniska högskola (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:International Journal of Environmental Research and Public Health: MDPI AG14:2, s. 137-1661-78271660-4601

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Romano, Francesc ...
Gusten, Jan, 195 ...
Antonellis, Stef ...
Joppolo, Cesare ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Annan medicin oc ...
Artiklar i publikationen
International Jo ...
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy