Air leakage variations due to changes in moisture content in wooden construction- magnitudes and consequences

Domhagen, Fredrik, 1987 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Wahlgren, Paula, 1967 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
 (creator_code:org_t)
2017
2017
Engelska.
Ingår i: Proceedings AIVC38th AIVC Conference, Nottingham, United Kingdom, 2017.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • The airtightness of buildings is important for several reasons, such as being a prerequisite for low-energy buildings and for a healthy indoor air quality (without i.e. mold or radon). The airtightness of buildings can vary over time and investigations are made on these variations due to moisture induced movements in wooden constructions, and subsequent consequences, using both measurements and numerical simulations. Measurements were performed in a wooden guest house that was built in a laboratory hall with an approximate relative humidity of 30 %. The guest house was designed with a wind barrier but without a moisture barrier, and with a majority of the leakages situated in the wall/floor connection. The relative humidity in the guest house was varied so that the indoor relative humidity was kept at 90 % during 8 days and then decreased to 25 % during 7 days. This variation in moisture content in the wooden part can also illustrate the built in moisture in construction timber (starting at a moisture content of 16%). The air permeability was measured frequently during both periods and showed a change in air permeability from 0.74 l/sm2 to 1.21 l/sm2 at 50 Pa pressure difference. Consequently, for a wooden construction with a moisture dependent air permeability, it is easier to fulfill airtightness demands (checked by measurements), when the building is just erected, compared to a couple of months later. Numerical simulations on the moisture induced leakage variations and the impact of the resulting variation in air permeability are performed in Simulink and MATLAB. Air leakage is calculated using a set of object oriented functions within the MATLAB environment. These functions follow the same mathematical principle as presented in the airflow simulation software CONTAM. The simulations are made for the climate of Gothenburg in south-west part of Sweden.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering (hsv//eng)

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Domhagen, Fredri ...
Wahlgren, Paula, ...
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
Artiklar i publikationen
Av lärosätet
Chalmers tekniska högskola

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy