SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Neubert Markus)
 

Search: WFRF:(Neubert Markus) > Measuring and Separ...

  • Kersten, Anton,1991Chalmers tekniska högskola,Chalmers University of Technology (author)

Measuring and Separating Conducted Three-Wire Emissions from a Fault-Tolerant, NPC Propulsion Inverter with a Split-Battery Using Hardware Separators Based on HF Transformers

  • Article/chapterEnglish2021

Publisher, publication year, extent ...

  • 2021
  • electronicrdacarrier

Numbers

  • LIBRIS-ID:oai:research.chalmers.se:889fed91-3b71-4cb4-9c6d-2a24b7e182fe
  • https://doi.org/10.1109/TPEL.2020.3000586DOI
  • https://research.chalmers.se/publication/519376URI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:art swepub-publicationtype
  • Subject category:ref swepub-contenttype

Notes

  • Conducted emissions on the traction battery's power cables in EVs must be limited to avoid unwanted electromagnetic interference (EMI). When designing an EMI filter, it is advantageous to have information of the common mode (CM) and differential mode (DM) noise levels. This article deals with the measurement and separation of the dc side's three-wire DM/CM noise of a fault-tolerant three-level neutral-point-clamped (NPC) inverter with a split-battery system. Two hardware separators, based on small-circuit highfrequency transformers, were developed to identify the dc side's CM, line-DM, and phase-DM noise levels. Their characterized CM and DM rejection ratios for the frequency range from 150 kHz to 110 MHz are at least -33 and -21 dB, respectively. The separated noise of the NPC inverter was measured, using an inductive load, when operating the inverter with three-level and two-level modulation, resembling normal operation and a possible operation under fault, respectively. A simple three-wire CM model of the used testbed and the DM power module oscillation were derived to validate the separated noise's resonance peaks/valleys. It has been seen that the CM noise is dominant, especially below 10 MHz, except for the power module oscillations. Furthermore, when using the two-level modulation, in the case of a clamping diode fault, the noise levels are increased by about 3 dB.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Oberdieck, KarlRheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University (author)
  • Gossmann, JeromeRheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University (author)
  • Bubert, AndreasRheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University (author)
  • Loewenherz, RolfRheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University (author)
  • Neubert, MarkusRheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University (author)
  • Thiringer, Torbjörn,1966Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)thorbear (author)
  • Doncker, Rik W.DeRheinisch-Westfaelische Technische Hochschule Aachen,RWTH Aachen University (author)
  • Chalmers tekniska högskolaRheinisch-Westfaelische Technische Hochschule Aachen (creator_code:org_t)

Related titles

  • In:IEEE Transactions on Power Electronics36:1, s. 378-3900885-89931941-0107

Internet link

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view