SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:8fb614b1-70dc-41ee-8f49-7349b6fe8d35"
 

Sökning: onr:"swepub:oai:research.chalmers.se:8fb614b1-70dc-41ee-8f49-7349b6fe8d35" > Some aspects on the...

  • Romano, FrancescoPolitecnico di Milano,Polytechnic University of Milan (författare)

Some aspects on the sampling efficiency of microbial impaction air samplers

  • Artikel/kapitelEngelska2015

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2015

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:8fb614b1-70dc-41ee-8f49-7349b6fe8d35
  • https://doi.org/10.1016/j.partic.2014.11.008DOI
  • https://research.chalmers.se/publication/218300URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • Indoor microbial monitoring is an important health issue in many sectors of society. In particular, it is important to monitor microbial concentrations in environments dealing with bio-susceptible products. Many human diseases are related to high, undesired microbial airborne concentrations. However, the lack of a standardized and well-accepted methodology for testing and ranking the performance of microbial air samplers is a source of uncertainty in such measurements. Several works clearly show that results obtained from microbial air sampling depend largely on measuring techniques, especially the air samplers' physical parameters, such as d(50), as well as environmental conditions, sources, and concentrations of microbial organisms in the environment. Furthermore, personnel using cleanroom clothing can reduce the microbial burden within a clean environment. To evaluate this effect, we carried out experimental comparison tests in a cleanroom of class ISO 5 with different air samplers under various microbial concentration levels, generated by a human source dressed in different quality cleanroom clothing. Our results confirm that in addition to the measuring technique, cleanroom clothing does influence microbial contamination, affecting air sampler measurements.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Gusten, Jan,1952Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)guste (författare)
  • Joppolo, Cesare M.Politecnico di Milano,Polytechnic University of Milan (författare)
  • Ljungqvist, Bengt,1946Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)bengtlj (författare)
  • Reinmüller, Berit,1939Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)beritr (författare)
  • Politecnico di MilanoChalmers tekniska högskola (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Particuology: Elsevier BV20, s. 110-1132210-42911674-2001

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy