SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Tagaya M)
 

Sökning: WFRF:(Tagaya M) > Reusable hydroxyapa...

  • Tagaya, M.Tokyo Institute of Technology,National Institute for Materials Science (NIMS) (författare)

Reusable hydroxyapatite nanocrystal sensors for protein adsorption

  • Artikel/kapitelEngelska2010

Förlag, utgivningsår, omfång ...

  • 2016-01-12
  • Informa UK Limited,2010

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:9e7ec30f-8199-4cc0-a16d-1f85250de2e5
  • https://doi.org/10.1088/1468-6996/11/4/045002DOI
  • https://research.chalmers.se/publication/128707URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:kon swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • The repeatability of the adsorption and removal of fibrinogen and fetal bovine serum on hydroxyapatite (HAp) nanocrystal sensors was investigated by Fourier transform infrared (FTIR) spectroscopy and quartz crystal microbalance with dissipation (QCM-D) monitoring technique. The HAp nanocrystals were coated on a gold-coated quartz sensor by electrophoretic deposition. Proteins adsorbed on the HAp sensors were removed by (i) ammonia/hydrogen peroxide mixture (APM), (ii) ultraviolet light (UV), (iii) UV/APM, (iv) APM/UV and (v) sodium dodecyl sulfate (SDS) treatments. FTIR spectra of the reused surfaces revealed that the APM and SDS treatments left peptide fragments or the proteins adsorbed on the surfaces, whereas the other methods successfully removed the proteins. The QCM-D measurements indicated that in the removal treatments, fibrinogen was slowly adsorbed in the first cycle because of the change in surface wettability revealed by contact angle measurements. The SDS treatment was not effective in removing proteins. The APM or UV treatment decreased the frequency shifts for the reused HAp sensors. The UV/APM treatment did not induce the frequency shifts but decreased the dissipation shifts. Therefore, we conclude that the APM/UV treatment is the most useful method for reproducing protein adsorption behavior on HAp sensors.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Ikoma, T.Tokyo Institute of Technology,National Institute for Materials Science (NIMS) (författare)
  • Hanagata, N.National Institute for Materials Science (NIMS) (författare)
  • Chakarov, Dinko,1955Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)f7xdc (författare)
  • Kasemo, Bengt Herbert,1942Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)kasemo (författare)
  • Tanaka, J.Tokyo Institute of Technology (författare)
  • Tokyo Institute of TechnologyNational Institute for Materials Science (NIMS) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Science and Technology of Advanced Materials: Informa UK Limited11:41468-69961878-5514

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy