SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Angseryd Jenny 1979)
 

Sökning: WFRF:(Angseryd Jenny 1979) > Quantitative atom p...

Quantitative atom probe analysis of carbides

Thuvander, Mattias, 1968 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Weidow, Jonathan, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Angseryd, Jenny, 1979 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Falk, Lena, 1956 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Liu, Fang, 1975 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Sonestedt, Marie, 1981 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Stiller, Krystyna Marta, 1947 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Andrén, Hans-Olof, 1947 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
Elsevier BV, 2011
2011
Engelska.
Ingår i: Ultramicroscopy. - : Elsevier BV. - 1879-2723 .- 0304-3991. ; 111:6, s. 604-608
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Compared to atom probe analysis of metallic materials, the analysis of carbide phases results in an enhanced formation of molecular ions and multiple events. In addition, many multiple events appear to consist of two or more ions originating from adjacent sites in the material. Due to limitations of the ion detectors measurements generally underestimate the carbon concentration. Analyses using laser-pulsed atom probe tomography have been performed on SiC, WC, Ti(C,N) and Ti 2 AlC grains in different materials as well as on large M 2 3C 6 precipitates in steel. Using standard evaluation methods, the obtained carbon concentration was 6-24% lower than expected from the known stoichiometry. The results improved remarkably by using only the 13 C isotope, and calculating the concentration of 12 C from the natural isotope abundance. This confirms that the main reason for obtaining a too low carbon concentration is the dead time of the detector, mainly affecting carbon since it is more frequently evaporated as multiple ions. In the case of Ti(C,N) andTi 2 AlC an additional difficulty arises from the overlap between C 2 + ,C 2+ 4 and Ti 2+ at the mass-to-charge 24 Da. © 2010 Elsevier B.V.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Annan materialteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Other Materials Engineering (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy