Control methods for a direct-ground cooling system: An experimental study on office cooling with ground-coupled ceiling cooling panels

  • Artikel/kapitelEngelska2019

Förlag, utgivningsår, omfång ...

  • Elsevier BV,2019

Nummerbeteckningar

  • LIBRIS-ID:oai:research.chalmers.se:ac1ef121-a7d5-4e2d-a373-bf275b5a34b9
  • https://doi.org/10.1016/j.enbuild.2019.05.049DOI
  • https://research.chalmers.se/publication/510533URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:art swepub-publicationtype
  • Ämneskategori:ref swepub-contenttype

Anmärkningar

  • This article experimentally investigates the performance of two control methods (the supply water temperature method and the water flow control method)for a direct-ground cooling system. The control methods were implemented through three types of indoor feedback controllers: 1)an on/off controller, 2)an on/off controller with a deadband and 3)P controller. The performances of the control methods were evaluated regarding room temperature stability and pump energy use. Ceiling cooling panels were employed to keep the test room air temperature at 25.0 °C under periodic heat gain conditions. The cooling system used a ground heat exchanger with a U-pipe in an 80-meter-deep borehole as a cooling source. The findings show that room air temperature was maintained close to the set-point with both control methods, but it was more stable with the temperature control method. In addition, condensation risk was easily preventable with the temperature control method. A parametric study showed that pump energy use when using two-position controllers could be as low as when using modulating controllers if the on-state flow rate of the circulating pump is selected in relation to the ground temperature and heat transfer characteristics of the heat exchanger.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Javed, Saqib,1978Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)javeds (författare)
  • Trüschel, Anders,1970Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)m92tran (författare)
  • Dalenbäck, Jan-Olof,1954Chalmers tekniska högskola,Chalmers University of Technology(Swepub:cth)jod (författare)
  • Chalmers tekniska högskola (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Energy and Buildings: Elsevier BV197, s. 47-560378-7788

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy