SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Mancusi Davide 1980)
 

Sökning: WFRF:(Mancusi Davide 1980) > Shielding of relati...

Shielding of relativistic protons

Bertucci, Antonella (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
Durante, Marco (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
Gialanella, Giancarlo (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
visa fler...
Grossi, Gianfranco (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
Manti, Lorenzo (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
Pugliese, Mariagabriella (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
Scampoli, Paola (författare)
Universita Degli Studi Di Napoli Federico Ii,University of Naples Federico II
Mancusi, Davide, 1980 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Sihver, Lembit, 1962 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Rusek, Adam (författare)
Brookhaven National Laboratory
visa färre...
 (creator_code:org_t)
2007-01-26
2007
Engelska.
Ingår i: Radiation and Environmental Biophysics. - : Springer Science and Business Media LLC. - 1432-2099 .- 0301-634X. ; 46:2, s. 107-111
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Protons are the most abundant element in the galactic cosmic radiation, and the energy spectrum peaks around 1 GeV. Shielding of relativistic protons is therefore a key problem in the radiation protection strategy of crewmembers involved in long-term missions in deep space. Hydrogen ions were accelerated up to 1 GeV at the NASA Space Radiation Laboratory, Brookhaven National Laboratory, New York. The proton beam was also shielded with thick ( about 20 g/cm(2)) blocks of lucite (PMMA) or aluminium ( Al). We found that the dose rate was increased 40-60% by the shielding and decreased as a function of the distance along the axis. Simulations using the General Purpose Particle and Heavy-Ion Transport code System (PHITS) show that the dose increase is mostly caused by secondary protons emitted by the target. The modified radiation Weld after the shield has been characterized for its biological eVectiveness by measuring chromosomal aberrations in human peripheral blood lymphocytes exposed just behind the shield block, or to the direct beam, in the dose range 0.53 Gy. Notwithstanding the increased dose per incident proton, the fraction of aberrant cells at the same dose in the sample position was not significantly modified by the shield. The PHITS code simulations show that, albeit secondary protons are slower than incident nuclei, the LET spectrum is still contained in the low-LET range (

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Annan teknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Other Engineering and Technologies (hsv//eng)

Nyckelord

RISK
ABERRATIONS
HUMAN-LYMPHOCYTES
ENERGY IRON IONS

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy