SwePub
Sök i LIBRIS databas

  Utökad sökning

onr:"swepub:oai:research.chalmers.se:d53b06fb-8840-45dd-8269-f1badd4e8eae"
 

Sökning: onr:"swepub:oai:research.chalmers.se:d53b06fb-8840-45dd-8269-f1badd4e8eae" > A Frequency Selecti...

A Frequency Selective Surface based focal plane receiver for the OLIMPO balloon-borne telescope

Mahashabde, Sumedh, 1985 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Sobolev, Alexander (författare)
National Research University of Electronic Technology (MIET),M. V. Lomonosov Moscow State University
Bengtsson, Andreas, 1991 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa fler...
Andrén, Daniel, 1991 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Tarasov, Mikhail, 1954 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
Salatino, Maria, 1983 (författare)
Universita degli Studi di Roma la Sapienza,Sapienza University of Rome
de Bernardis, P. (författare)
Universita degli Studi di Roma la Sapienza,Sapienza University of Rome
Masi, S. (författare)
Universita degli Studi di Roma la Sapienza,Sapienza University of Rome
Kuzmin, Leonid, 1946 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
2015
2015
Engelska.
Ingår i: IEEE Transactions on Terahertz Science and Technology. - 2156-342X .- 2156-3446. ; 5:1, s. 145-152
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • We describe here a focal plane array of Cold-Electron Bolometer (CEB) detectors integrated in a Frequency Selective Surface (FSS) for the 350 GHz detection band of the OLIMPO balloon-borne telescope. In our architecture, the two terminal CEB has been integrated in the periodic unit cell of the FSS structure and is impedance matched to the embedding impedance seen by it and provides a resonant interaction with the incident sub-mm radiation. The detector array has been designed to operate in background noise limited condition for incident powers of 20 pW to 80 pW, making it possible to use the same pixel in both photometric and spectrometric configurations. We present high frequency and dc simulations of our system, together with fabrication details. The frequency response of the FSS array, optical response measurements with hot/cold load in front of optical window and with variable temperature black body source inside cryostat are presented. A comparison of the optical response to the CEB model and estimations of Noise Equivalent power (NEP) is also presented.

Ämnesord

NATURVETENSKAP  -- Fysik -- Astronomi, astrofysik och kosmologi (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Astronomy, Astrophysics and Cosmology (hsv//eng)
NATURVETENSKAP  -- Fysik -- Den kondenserade materiens fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Condensed Matter Physics (hsv//eng)

Nyckelord

Cold Electron Bolometer
Frequency Selective Surface
OLIMPO

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy