SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0277 786X OR L773:1996 756X OR L773:9781510609594
 

Sökning: L773:0277 786X OR L773:1996 756X OR L773:9781510609594 > (2020-2024) > 5.3 THz MgB 2 hot e...

5.3 THz MgB 2 hot electron bolometer mixer operated at 20 K

Gao, J. R. (författare)
Technische Universiteit Delft,Delft University of Technology (TU Delft),Netherlands Institute for Space Research (SRON)
Gan, Y. (författare)
Rijksuniversiteit Groningen,University of Groningen,Netherlands Institute for Space Research (SRON)
Mirzaei, B. (författare)
Technische Universiteit Delft,Delft University of Technology (TU Delft),Netherlands Institute for Space Research (SRON)
visa fler...
Silva, J. R.G.D. (författare)
Rijksuniversiteit Groningen,University of Groningen,Netherlands Institute for Space Research (SRON)
Cherednichenko, Serguei, 1970 (författare)
Chalmers tekniska högskola,Chalmers University of Technology
visa färre...
 (creator_code:org_t)
SPIE, 2022
2022
Engelska.
Ingår i: Proceedings of SPIE - The International Society for Optical Engineering. - : SPIE. - 0277-786X .- 1996-756X. ; 12190
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Heterodyne receivers combining a NbN HEB mixer with a local oscillator (LO) are the work horse for high resolution (≥106) spectroscopic observations at supra-Terahertz frequencies. We report an MgB2 HEB mixer working at 5.3 THz with 20 K operation temperature based on a previously published paper [Y. Gan et al, Appl. Phys. Lett., 119, 202601 (2021)]. The HEB consists of a 7 nm thick MgB2 submicron-bridge contacted with a spiral antenna. It has a Tc of 38.4 K. By using hot/cold blackbody loads and a Mylar beam splitter all in vacuum, and applying a 5.25 THz FIR gas laser as the LO, we measured a minimal DSB receiver noise temperature of 3960 K. The latter gives a DSB mixer noise temperature of 1470 K. This sensitivity is 28 times better than a room temperature Schottky mixer at 4.7 THz, but about 2.5 times less sensitive than an NbN HEB mixer. The latter must be operated around 4 K. The IF noise bandwidth is about 10 GHz, which is 2.5-3 times larger than an NbN HEB. With further optimization, such MgB2 HEBs are expected to reach a better sensitivity. That the low noise, wide IF bandwidth MgB2 HEB mixers can be operated in a compact, low dissipation 20 K Stirling cooler can significantly reduce the cost and complexity of heterodyne instruments and therefore facilitate new space missions.

Ämnesord

NATURVETENSKAP  -- Fysik -- Annan fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Other Physics Topics (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Signalbehandling (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Signal Processing (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

IF bandwidth
Mixer
MgB2
High Tc
Space instrumentation
THz
Superconductor
Hot electron bolometer

Publikations- och innehållstyp

kon (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy