Sökning: id:"swepub:oai:research.chalmers.se:f19c192a-afb6-4e6a-b77b-1ef95eebf3da" >
Photon-noise-limite...
Photon-noise-limited cold-electron bolometer based on strong electron self-cooling for high-performance cosmology missions
-
- Kuzmin, Leonid, 1946 (författare)
- Nizhny Novgorod State Technical University,Chalmers tekniska högskola,Chalmers University of Technology
-
- Pankratov, A. L. (författare)
- Nizhny Novgorod State Technical University,Russian Academy of Sciences
-
- Gordeeva, A. V. (författare)
- Russian Academy of Sciences,Nizhny Novgorod State Technical University
-
visa fler...
-
- Zbrozhek, V. O. (författare)
- Nizhny Novgorod State Technical University
-
- Shamporov, V. A. (författare)
- Russian Academy of Sciences,Nizhny Novgorod State Technical University
-
- Revin, L. S. (författare)
- Nizhny Novgorod State Technical University,Russian Academy of Sciences
-
- Blagodatkin, A. V. (författare)
- Russian Academy of Sciences,Nizhny Novgorod State Technical University
-
- Masi, S. (författare)
- Universita degli Studi di Roma la Sapienza,Sapienza University of Rome
-
- de Bernardis, P. (författare)
- Universita degli Studi di Roma la Sapienza,Sapienza University of Rome
-
visa färre...
-
(creator_code:org_t)
- 2019-09-03
- 2019
- Engelska.
-
Ingår i: Communications Physics. - : Springer Science and Business Media LLC. - 2399-3650. ; 2:1
- Relaterad länk:
-
https://research.cha... (primary) (free)
-
visa fler...
-
https://www.nature.c...
-
https://research.cha...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Bolometers for balloon and space missions have seen extensive development because of their capacity to test primordial conditions of the Universe. The major improvements consist in lowering the operating temperature to reach higher sensitivities. Here we show that an array of 192 cold-electron bolometers (CEB) demonstrates photon-noise-limited operation at the cryostat temperature of 310 mK due to effective self-cooling of the absorber. The direct electron cooling of nanoabsorber placed between normal metal - insulator - superconductor junctions has considerably higher efficiency than indirect cooling through massive suspended platform, that requires overcoming a weak electron-phonon conductance. The electron temperature reached 120 mK without a power load, and 225 mK with a 60 pW power load with self-noise of a single bolometer below 3⋅10-18WHz-1∕2 at a 0.01 pW power load. This bolometer works at electron temperature less than phonon temperature, thus being a good candidate for future space missions without the use of dilution refrigerators.
Ämnesord
- TEKNIK OCH TEKNOLOGIER -- Maskinteknik -- Energiteknik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Mechanical Engineering -- Energy Engineering (hsv//eng)
- NATURVETENSKAP -- Fysik -- Annan fysik (hsv//swe)
- NATURAL SCIENCES -- Physical Sciences -- Other Physics Topics (hsv//eng)
- TEKNIK OCH TEKNOLOGIER -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
- ENGINEERING AND TECHNOLOGY -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
Publikations- och innehållstyp
- art (ämneskategori)
- ref (ämneskategori)
Hitta via bibliotek
Till lärosätets databas
- Av författaren/redakt...
-
Kuzmin, Leonid, ...
-
Pankratov, A. L.
-
Gordeeva, A. V.
-
Zbrozhek, V. O.
-
Shamporov, V. A.
-
Revin, L. S.
-
visa fler...
-
Blagodatkin, A. ...
-
Masi, S.
-
de Bernardis, P.
-
visa färre...
- Om ämnet
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Maskinteknik
-
och Energiteknik
-
- NATURVETENSKAP
-
NATURVETENSKAP
-
och Fysik
-
och Annan fysik
-
- TEKNIK OCH TEKNOLOGIER
-
TEKNIK OCH TEKNO ...
-
och Elektroteknik oc ...
-
och Annan elektrotek ...
- Artiklar i publikationen
-
Communications P ...
- Av lärosätet
-
Chalmers tekniska högskola